Commit Graph

469 Commits

Author SHA1 Message Date
aaronlong
7ee4fae5ad Added tcUNIT, including helper functions and app test folder, to generic structure 2019-12-24 10:08:59 +00:00
Federico Rojas
d0201452f6 Merged in MBP-111-bug-error-4b07-immediately-after (pull request #25)
Change TC2_MC library version to 3.3.28

Approved-by: Torsten Bögershausen <torsten.bogershausen@esss.se>
2019-12-18 16:28:34 +00:00
Federico Rojas
6e0735106d Change PLCtask cycle time to 10ms 2019-12-18 17:19:00 +01:00
Federico Rojas
0532cb9214 Remove PLCTask1 from solution 2019-12-18 17:16:49 +01:00
Federico Rojas
91b18c6e73 Change TC2_MC library version to 3.3.28
No jogging error with this library version
2019-12-18 16:44:53 +01:00
Paul Barron
f360d382a1 Update to latest commit of tc_mca_std_lib
Remove variable fHomePosition which was defined twice
2019-12-18 16:33:53 +01:00
Paul Barron
4af4094855 Change PLC cycle time to 10ms 2019-12-18 15:30:38 +01:00
Paul Barron
200ff88e6f Update to latest commit of tc_mca_std_lib 2019-12-18 15:26:33 +01:00
Paul Barron
646085d03b Update tc_mca_std_lib to latest version 2019-12-18 10:57:49 +01:00
Paul Barron
04c7827a7a Merge 'tc_generic_struct/integration' into mbp-77/191217-RemoveMode2
Conflicts:
	solution/solution.tsproj
	solution/tc_project_app/GVLs/GVL_APP.TcGVL
	solution/tc_project_app/POUs/MAIN.TcPOU
	solution/tc_project_app/tc_project_app.plcproj
2019-12-18 10:48:04 +01:00
Paul Barron
b61bf93b52 Remove hardware and rebuild
Change axisNum to 2
2019-12-17 14:54:20 +01:00
Paul Barron
4a59909ff1 Update to latest commit in tc_mca_std_lib
Commented out mode 2 in position restore
2019-12-17 14:49:07 +01:00
Paul Barron
1c9d8f3b6b Remove mode 2 from position restore
It was decided in a code review that mode 2 wasn't doing exactly as we wanted
and that it probably wasn't required, at least for now.
Changes to logic so that the position restore is only done after a power cycle and
not a download, reset cold or reset origin.
2019-12-17 14:46:55 +01:00
Paul Barron
e36d4bcab3 Change comment 2019-12-17 10:37:24 +01:00
Paul Barron
5d5ee5f4ad Add latest commit for tc_mca_std_lib 2019-12-17 10:33:57 +01:00
Paul Barron
5743a13513 Remove mode 2 from iRestoreCode
Issues found regarding overiding of .config params in the axis struct.
Also doubts about whether it would actually be used.
2019-12-17 10:27:25 +01:00
Federico Rojas
094480f040 Update submodules to latest versions to pass the white space test 2019-12-13 15:21:12 +01:00
Federico Rojas
29f11a6db0 Rebuild solution after deletting the NC folder and content 2019-12-13 14:45:20 +01:00
Federico Rojas
c68218106e Delete the NC folder under _Config folder
There was some Axis infomation and this branch should not have HW. I delete the folder and the content
Delete _Config/NC
2019-12-13 14:35:31 +01:00
Paul Barron
e000543a7f Add ST_AxisPersistent.TcDUT to generic structure 2019-12-13 13:45:50 +01:00
Paul Barron
5570b03fad Changes inside tc_mca_std_lib
Moved persistent variables from MAIN to a new struct in the generic_structure
called ST_AxisPersistent
2019-12-13 13:44:16 +01:00
Paul Barron
f1063b56d7 Change names of MAIN.STARTUP and MAIN.SHUTDOWN
Change to MAIN.RESTORE_POSITIONS and MAIN.STORE_PERSISTENT
Bug fix: add check in MAIN.RESTORE_POSITIONS to check whether
an axis was moving at shutdown.
Variable name changes to acommodate moving the persistent variables
from MAIN to a DUT in the generic structure.
2019-12-13 13:41:25 +01:00
Paul Barron
f2d73d013f Fix whitespace damage
No code changes
2019-12-11 15:24:00 +01:00
Paul Barron
3b633b1487 Changes in tc_mca_std_lib
No changes in tc_general_struct in this commit
2019-12-11 15:22:36 +01:00
Paul Barron
a9d5e51ac0 Added saving of position values throughout the normal PLC cycle
Added a check in MAIN.SHUTDOWN that makes sure the restore  has been
done first before starting to save values again.
Probably should change the name from MAIN.SHUTDOWN to MAIN.SAVEVALUES or something.
2019-12-11 15:17:59 +01:00
Paul Barron
10ef1a594d Remove MAIN.SHUTDOWN from ordinary PLC cycle
This created a problem in that MAIN.STARTUP wasn't working correctly
because it takes a couple of cycles to complete and MAIN.SHUTDOWN
was overriding the values stored after a power loss. Thus the restore won't work
for a user cold reset. It can be catered for by adding it back into the ordinary PLC
cycle but only executing if bPositionRestoreDone is set.
2019-12-11 15:02:11 +01:00
Paul Barron
df44dd3b82 Bug fix: add additional check in MAIN.SHUTDOWN
gvl.axes[i].Axis.Status.Moving doesn't seem to work if the axis isn't enabled.
Therefore added a check to see whether gvl.axes[i].Axis.NcToPlc.ActVelo <> 0.
If it's non-zero then don't restore the encoder value on restart.
MAIN.SHUTDOWN also added to the normal operation cycle, this is to allow restart
after a "Reset Cold" command in Visual Studio, otherwise the only time position is
restored is an actual lose of power. It might be also useful when a user restarts
the PLC program manually.
Also modified a few comments in MAIN.STARTUP.
2019-12-11 14:28:54 +01:00
Paul Barron
83f1b66c9b Fix white space damage 2019-12-11 13:57:26 +01:00
Paul Barron
480f4098bb Moved the cycle through of the read parameter fbs inside if statement
Motivation: after the position restore code has executed successfully
there is no point running any of the code again and wasting PLC cycles.
Thus the first step in the MAIN.STARTUP is a check whether the code has
been completed or not. If it is has completed successfully ignore everything else.
2019-12-11 13:54:19 +01:00
Paul Barron
534a318269 Remove timer tmrRetry from MAIN.STARTUP
No longer required in the restore position state machine code.
If the read parameter function block isn't successful it will go back
a set in the case statement and try again.
The read parameter function block, fbReadEncRefSys, reads the type of axis
either inc or abs.
2019-12-11 13:35:50 +01:00
Paul Barron
090fbd03eb Lots of changes in MAIN.STARTUP
Changes to the way the code checks whether the enc type is valid.
Added a parameter to the axis struct for setting a homing value other than 0.
2019-12-10 16:48:34 +01:00
aaronlong
80e4ea356e Submodule update: tc_mca_std_lib 2019-12-10 14:44:21 +00:00
Paul Barron
ac37748fbe Add comments to MAIN.STARTUP
Slight tidy of code but no structural changes.
2019-12-10 13:27:05 +01:00
Paul Barron
dbd145ed68 Add DUT RestorePosition in tc_mca_std_lib
Also adjusted code in MAIN.STARTUP to adapt to the new type variable
instead of the int previously.
2019-12-10 12:49:37 +01:00
Paul Barron
f7906d265a Readability change, make case statements easier to read
No code changes
2019-12-10 11:39:00 +01:00
Paul Barron
d88816156a Change to variable in axis struct for restore of incremental enc values on lose of power
Change iPositionRestore to ePosition restore.
Change from int to enum.
2019-12-10 11:37:34 +01:00
Paul Barron
c49d1d0faf Increase homing and jog speeds
For axis 1 and 2
2019-12-10 10:37:08 +01:00
Paul Barron
c6cac2ce7c Set monitoring parameters
E.g. position lag, target position etc.
Done for axis 1 and 2.
2019-12-10 10:26:57 +01:00
Paul Barron
f59a9dfccf Invert motor polarity for axis 1 2019-12-09 15:02:05 +01:00
Paul Barron
ad48a4c161 Invert encoder counting direction on axis 2 2019-12-09 14:57:14 +01:00
Paul Barron
dd4cfbe34b Set dynamic parameters for Axis 1 and 2 2019-12-09 14:49:00 +01:00
Paul Barron
57aa137e4e Change encoder scaling factor denominator to 2000
Done for axis 1 and 2
2019-12-09 14:43:50 +01:00
Paul Barron
173400e7f0 Change Reference Velocity to 600
Changed for axis 1 and 2
2019-12-09 14:41:16 +01:00
Paul Barron
35eb7a5261 Change encoder scaling factor to num=60 and den=1000
Done for axis 1 and 2
2019-12-09 14:30:44 +01:00
Paul Barron
b7ae38ad86 Change link of encoder for axis 1 and 2 to hardware terminals 2019-12-09 14:16:51 +01:00
Paul Barron
f36a636a4e Link hardware inputs to bLimitFwd, bLimitBwd, bLimitHome
Done for both axis 1 and 2.
2019-12-09 14:05:32 +01:00
Paul Barron
8b2779fe61 Link boutput 2,3,6,7 to the hardware 2019-12-09 13:32:10 +01:00
Paul Barron
c8775e5ae5 Create bOutput 2,3,6,7 for switches in MAIN.TcPOU
modified:   solution/solution.tsproj
	modified:   solution/tc_project_app/POUs/MAIN.TcPOU
2019-12-09 13:29:28 +01:00
Paul Barron
5fe5abbbf3 Link bOutput1 and bOutput5 to hardware 2019-12-09 13:27:22 +01:00
Paul Barron
d36efd414d Create bOutput5 for axis 2 switches 2019-12-09 13:25:06 +01:00