Fixes SICS-568 Because tasdrive now stops calling status checking on a
motor which has terminated for any reason.
SICS-570: The correct motor names are now reported by tasdrive.
SICS-575: Use ANSTO motor names when reporting limit violations.
the capture command in that it not put resluts into the Tcl interpreter.
This broke scriptcontext scripts in complicated situations.
- Resolved some issues with the TAS calculation and negative scattering sense.
- Fixed a bug which did not reset the state to idle after checking
reachability in confvirtualmot.c
SKIPPED:
psi/autowin.c
psi/eigera2.c
psi/jvlprot.c
psi/makefile_linux
psi/sinqhttpopt.c
psi/tasscan.c
- Removed generation of incommenurate reflections for 0,0,0 in fourmess.c
- Implemented a Poch command for heartbeats
- Fixed 64 bit dimension issues in nxdict
- Fixed different calling conventions for NXReportError deep stack in nxdict
- Stopped ei motor driving when not necessary
- Added yet another monitor for POLDI
- Added a protocoll driver for the JVL motor RS-485 binary protocoll
- Fixed some reporting issues
SKIPPED:
psi/jvlprot.c
psi/make_gen
psi/polterwrite.c
psi/psi.c
psi/spss7.c
- Fixed ei interrupt bug in tasdrive.c
- Made eiger A2 driving work
- Added force start facility to devexec for POLDI HV
SKIPPED:
psi/eigera2.c
psi/polterwrite.c
to fourmess
- Fixed hdbtable, reflist and tasub up to work with GTSE
- Made TRICS do fast scans again
- Added support for SANS beam center calculations
- Fixed a bug where SICS apparently did double counting but in fact
just omitted an error message and did not
- Added the harray command
- Fixed new AMOR settings module
- Initial implementation of the new SICS hierarchical parameter database
SKIPPED:
psi/amorset.c
psi/libpsi.a
psi/sps.c
- Mended tasdrive to drive energy even if Q is askew
- Fixed QM values
- Fixed problems in mesure: om2th, wrong theta selection
- Fixed core dump when driving h,kl, failed
reached: it handles one test case correctly back and forth
- Fixed oscillation code
- Added a feature for switching off automatic updates in nxupdate
Autoamtic updates cause problems when scanning...