10 Commits
1.1.2 ... 1.2.2

Author SHA1 Message Date
954fc82414 Moved error handling out of error read condition.
Some checks failed
Test And Build / Lint (push) Failing after 9s
Test And Build / Build (push) Successful in 12s
Previously, error messaging was only done after the error has been read.
This means that cached errors were simply ignored, if e.g. the motor was
moving. This commit now messages an error as long as it exists in the
cache "masterMacsAxisImpl->axisError".
2025-08-05 09:04:11 +02:00
ff183576ec Added axis reinitialization after node reset
When resetting the node, values within the controller may change, which
need to be reread by the init function.
2025-08-05 08:58:50 +02:00
83f9be3be8 Switched to forcedPoll method 2025-07-24 13:20:30 +02:00
2c0c9a33b7 Updated sinqMotor version 2025-07-24 13:19:24 +02:00
8bb81b1716 Fixed wrong comments
Some checks failed
Test And Build / Lint (push) Failing after 4s
Test And Build / Build (push) Successful in 8s
2025-07-22 17:13:09 +02:00
c32708e49c Removed lastSpeed caching
Some checks failed
Test And Build / Lint (push) Failing after 4s
Test And Build / Build (push) Successful in 7s
After discussion with Sven Schlienger, I now send the new speed
unconditionally before each move command. This also means that the
caching of the last speed is no longer needed.
2025-07-16 11:23:37 +02:00
14a733fb67 adds gitea action
Some checks failed
Test And Build / Lint (push) Failing after 4s
Test And Build / Build (push) Successful in 8s
2025-07-04 14:18:44 +02:00
64b932c3ae Fixed bug 2025-07-01 10:05:39 +02:00
09897b6125 Added node reset to doReset 2025-07-01 10:03:20 +02:00
9d47cd4e24 Fixed docs 2025-06-18 09:26:32 +02:00
5 changed files with 211 additions and 232 deletions

View File

@@ -0,0 +1,24 @@
name: Test And Build
on: [push]
jobs:
Lint:
runs-on: linepics
steps:
- name: checkout repo
uses: actions/checkout@v4
- name: cppcheck
run: cppcheck --std=c++17 --addon=cert --addon=misc --error-exitcode=1 src/*.cpp
- name: formatting
run: clang-format --style=file --Werror --dry-run src/*.cpp
Build:
runs-on: linepics
steps:
- name: checkout repo
uses: actions/checkout@v4
with:
submodules: 'true'
- run: |
sed -i 's/ARCH_FILTER=.*/ARCH_FILTER=linux%/' Makefile
echo -e "\nIGNORE_SUBMODULES += sinqmotor" >> Makefile
make install

View File

@@ -1,48 +0,0 @@
default:
image: docker.psi.ch:5000/sinqdev/sinqepics:latest
stages:
- lint
- build
- test
cppcheck:
stage: lint
script:
- cppcheck --std=c++17 --addon=cert --addon=misc --suppress=cert-STR07-C --error-exitcode=1 src/*.cpp
artifacts:
expire_in: 1 week
tags:
- sinq
formatting:
stage: lint
script:
- clang-format --style=file --Werror --dry-run src/*.cpp
artifacts:
expire_in: 1 week
tags:
- sinq
build_module:
stage: build
script:
- export SINQMOTOR_VERSION="$(grep 'sinqMotor_VERSION=' Makefile | cut -d= -f2)"
- git clone --depth 1 --branch "${SINQMOTOR_VERSION}" https://gitlab-ci-token:${CI_JOB_TOKEN}@git.psi.ch/sinq-epics-modules/sinqmotor.git
- pushd sinqmotor
- sed -i 's/ARCH_FILTER=.*/ARCH_FILTER=linux%/' Makefile
- echo "LIBVERSION=${SINQMOTOR_VERSION}" >> Makefile
- make install
- popd
- sed -i 's/ARCH_FILTER=.*/ARCH_FILTER=linux%/' Makefile
- echo "LIBVERSION=${CI_COMMIT_TAG:-0.0.1}" >> Makefile
- make install
- cp -rT "/ioc/modules/masterMacs/$(ls -U /ioc/modules/masterMacs/ | head -1)" "./masterMacs-${CI_COMMIT_TAG:-$CI_COMMIT_SHORT_SHA}"
artifacts:
name: "masterMacs-${CI_COMMIT_TAG:-$CI_COMMIT_SHORT_SHA}"
paths:
- "masterMacs-${CI_COMMIT_TAG:-$CI_COMMIT_SHORT_SHA}/*"
expire_in: 1 week
when: always
tags:
- sinq

View File

@@ -55,11 +55,11 @@ setMaxSubsequentTimeouts("$(NAME)", 20);
setThresholdComTimeout("$(NAME)", 100, 1);
# Parametrize the EPICS record database with the substitution file named after the MCU.
epicsEnvSet("SINQDBPATH","$(sinqMotor_DB)/sinqMotor.db")
epicsEnvSet("SINQDBPATH","$(masterMacs_DB)/sinqMotor.db")
dbLoadTemplate("$(TOP)/$(NAME).substitutions", "INSTR=$(INSTR)$(NAME):,CONTROLLER=$(NAME)")
epicsEnvSet("SINQDBPATH","$(masterMacs_DB)/masterMacs.db")
dbLoadTemplate("$(TOP)/$(NAME).substitutions", "INSTR=$(INSTR)$(NAME):,CONTROLLER=$(NAME)")
dbLoadRecords("$(sinqMotor_DB)/asynRecord.db","P=$(INSTR)$(NAME),PORT=$(ASYN_PORT)")
dbLoadRecords("$(masterMacs_DB)/asynRecord.db","P=$(INSTR)$(NAME),PORT=$(ASYN_PORT)")
```
### Versioning

View File

@@ -19,7 +19,6 @@ struct masterMacsAxisImpl {
std::bitset<16> axisStatus;
std::bitset<16> axisError;
double lastSetSpeed;
bool waitForHandshake;
time_t timeAtHandshake;
bool needInit = true;
@@ -122,7 +121,6 @@ masterMacsAxis::masterMacsAxis(masterMacsController *pC, int axisNo)
pMasterMacsA_ = std::make_unique<masterMacsAxisImpl>((masterMacsAxisImpl){
.axisStatus = std::bitset<16>(0),
.axisError = std::bitset<16>(0),
.lastSetSpeed = 0.0,
.waitForHandshake = false,
.timeAtHandshake = 0,
.targetReachedUninitialized = true,
@@ -262,11 +260,6 @@ asynStatus masterMacsAxis::init() {
__PRETTY_FUNCTION__, __LINE__);
}
// Cache the motor speed. If this value differs from the one in the motor
// record at the start of a movement, the motor record value is sent to
// MasterMACS.
pMasterMacsA_->lastSetSpeed = motorVelocity;
// Store the motor position in the parameter library
pl_status = setMotorPosition(motorPosition);
if (pl_status != asynSuccess) {
@@ -439,184 +432,181 @@ asynStatus masterMacsAxis::doPoll(bool *moving) {
Read out the error if either a fault condition status flag has been set or
if a movement has just ended.
*/
if (faultConditionSet() || !(*moving)) {
rw_status = readAxisError();
}
msgPrintControlKey keyError = msgPrintControlKey(
pC_->portName, axisNo_, __PRETTY_FUNCTION__, __LINE__);
if (faultConditionSet() || !(*moving)) {
rw_status = readAxisError();
/*
A communication error is a special case. If a communication between
controller and axis error occurred, all subsequent errors are ignored,
since this information is not reliable.
*/
if (communicationError()) {
if (pC_->getMsgPrintControl().shouldBePrinted(keyError, true,
pC_->pasynUser())) {
asynPrint(pC_->pasynUser(), ASYN_TRACE_ERROR,
"Controller \"%s\", axis %d => %s, line "
"%d\nCommunication error.%s\n",
pC_->portName, axisNo_, __PRETTY_FUNCTION__, __LINE__,
pC_->getMsgPrintControl().getSuffix());
}
setAxisParamChecked(this, motorMessageText,
"Communication error between PC and motor "
"controller. Please call the support.");
poll_status = asynError;
} else {
// This buffer must be initialized to zero because we build the
// error message by appending strings.
char errorMessage[pC_->MAXBUF_] = {0};
char shellMessage[pC_->MAXBUF_] = {0};
// Concatenate all other errors
if (shortCircuit()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Short circuit fault.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Short circuit error. Please call the support.");
poll_status = asynError;
}
if (encoderError()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Encoder error.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Encoder error. Please call the support.");
poll_status = asynError;
}
if (followingError()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Maximum callowed following error exceeded.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Maximum allowed following error exceeded.Check if "
"movement range is blocked. Otherwise please call the "
"support.");
poll_status = asynError;
}
if (feedbackError()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Feedback error.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Feedback error. Please call the support.");
poll_status = asynError;
}
/*
A communication error is a special case. If a communication between
controller and axis error occurred, all subsequent errors are ignored,
since this information is not reliable.
*/
if (communicationError()) {
Either the software limits or the end switches of the controller
have been hit. Since the EPICS limits are derived from the software
limits and are a little bit smaller, these error cases can only
happen if either the axis has an incremental encoder which is not
properly homed or if a bug occured.
*/
if (positiveLimitSwitch() || negativeLimitSwitch() ||
positiveSoftwareLimit() || negativeSoftwareLimit()) {
// Distinction for developers
if (positiveLimitSwitch()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Positive limit switch.");
}
if (negativeLimitSwitch()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Negative limit switch.");
}
if (positiveSoftwareLimit()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Positive software limit.");
}
if (negativeSoftwareLimit()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Negative software limit.");
}
// Generic error message for user
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Software limits or end switch hit. Try homing the motor, "
"moving in the opposite direction or check the SPS for "
"errors (if available). Otherwise please call the "
"support.");
poll_status = asynError;
}
if (overCurrent()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Overcurrent error.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Overcurrent error. Please call the support.");
poll_status = asynError;
}
if (overTemperature()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Overtemperature error.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Overtemperature error. Please call the support.");
poll_status = asynError;
}
if (overVoltage()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Overvoltage error.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Overvoltage error. Please call the support.");
poll_status = asynError;
}
if (underVoltage()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Undervoltage error.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Undervoltage error. Please call the support.");
poll_status = asynError;
}
if (stoFault()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"STO input is on disable state.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"STO fault. Please call the support.");
poll_status = asynError;
}
if (strlen(shellMessage) > 0) {
if (pC_->getMsgPrintControl().shouldBePrinted(keyError, true,
pC_->pasynUser())) {
asynPrint(pC_->pasynUser(), ASYN_TRACE_ERROR,
"Controller \"%s\", axis %d => %s, line "
"%d\nCommunication error.%s\n",
"%d\n%s%s\n",
pC_->portName, axisNo_, __PRETTY_FUNCTION__, __LINE__,
pC_->getMsgPrintControl().getSuffix());
shellMessage, pC_->getMsgPrintControl().getSuffix());
}
setAxisParamChecked(this, motorMessageText,
"Communication error between PC and motor "
"controller. Please call the support.");
poll_status = asynError;
} else {
// This buffer must be initialized to zero because we build the
// error message by appending strings.
char errorMessage[pC_->MAXBUF_] = {0};
char shellMessage[pC_->MAXBUF_] = {0};
// Concatenate all other errors
if (shortCircuit()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Short circuit fault.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Short circuit error. Please call the support.");
poll_status = asynError;
}
if (encoderError()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Encoder error.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Encoder error. Please call the support.");
poll_status = asynError;
}
if (followingError()) {
appendErrorMessage(
shellMessage, sizeof(shellMessage),
"Maximum callowed following error exceeded.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Maximum allowed following error exceeded.Check if "
"movement range is blocked. Otherwise please call the "
"support.");
poll_status = asynError;
}
if (feedbackError()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Feedback error.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"Feedback error. Please call the support.");
poll_status = asynError;
}
/*
Either the software limits or the end switches of the controller
have been hit. Since the EPICS limits are derived from the software
limits and are a little bit smaller, these error cases can only
happen if either the axis has an incremental encoder which is not
properly homed or if a bug occured.
*/
if (positiveLimitSwitch() || negativeLimitSwitch() ||
positiveSoftwareLimit() || negativeSoftwareLimit()) {
// Distinction for developers
if (positiveLimitSwitch()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Positive limit switch.");
}
if (negativeLimitSwitch()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Negative limit switch.");
}
if (positiveSoftwareLimit()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Positive software limit.");
}
if (negativeSoftwareLimit()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Negative software limit.");
}
// Generic error message for user
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Software limits or end switch hit. Try homing the motor, "
"moving in the opposite direction or check the SPS for "
"errors (if available). Otherwise please call the "
"support.");
poll_status = asynError;
}
if (overCurrent()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Overcurrent error.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Overcurrent error. Please call the support.");
poll_status = asynError;
}
if (overTemperature()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Overtemperature error.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Overtemperature error. Please call the support.");
poll_status = asynError;
}
if (overVoltage()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Overvoltage error.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Overvoltage error. Please call the support.");
poll_status = asynError;
}
if (underVoltage()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"Undervoltage error.");
appendErrorMessage(
errorMessage, sizeof(errorMessage),
"Undervoltage error. Please call the support.");
poll_status = asynError;
}
if (stoFault()) {
appendErrorMessage(shellMessage, sizeof(shellMessage),
"STO input is on disable state.");
appendErrorMessage(errorMessage, sizeof(errorMessage),
"STO fault. Please call the support.");
poll_status = asynError;
}
if (strlen(shellMessage) > 0) {
if (pC_->getMsgPrintControl().shouldBePrinted(
keyError, true, pC_->pasynUser())) {
asynPrint(pC_->pasynUser(), ASYN_TRACE_ERROR,
"Controller \"%s\", axis %d => %s, line "
"%d\n%s%s\n",
pC_->portName, axisNo_, __PRETTY_FUNCTION__,
__LINE__, shellMessage,
pC_->getMsgPrintControl().getSuffix());
}
}
setAxisParamChecked(this, motorMessageText, errorMessage);
}
} else {
setAxisParamChecked(this, motorMessageText, errorMessage);
}
// No error has been detected -> Reset the error count
if (poll_status == asynSuccess) {
pC_->getMsgPrintControl().resetCount(keyError, pC_->pasynUser());
}
@@ -741,9 +731,7 @@ asynStatus masterMacsAxis::doMove(double position, int relative,
// Set the new motor speed, if the user is allowed to do so and if the
// motor speed changed since the last move command.
if (motorCanSetSpeed != 0 && pMasterMacsA_->lastSetSpeed != motorVelocity) {
pMasterMacsA_->lastSetSpeed = motorVelocity;
if (motorCanSetSpeed != 0) {
snprintf(value, sizeof(value), "%lf", motorVelocity);
status = pC_->write(axisNo_, 05, value);
@@ -815,16 +803,31 @@ asynStatus masterMacsAxis::stop(double acceleration) {
asynStatus masterMacsAxis::doReset() {
asynStatus status = pC_->write(axisNo_, 17, "");
asynStatus status = asynSuccess;
// Reset the controller ("node reset")
status = pC_->write(axisNo_, 16, "");
if (status != asynSuccess) {
setAxisParamChecked(this, motorStatusProblem, true);
}
// Reset the driver to idle state and move out of the handshake wait loop,
// if we're currently inside it.
// Reset any errors in the controller. Since the node reset results in a
// power cycle, we use the corresponding timeout.
status = pC_->write(axisNo_, 17, "", PowerCycleTimeout);
if (status != asynSuccess) {
setAxisParamChecked(this, motorStatusProblem, true);
}
// Move out of the handshake wait loop, if we're currently inside it.
pMasterMacsA_->waitForHandshake = false;
return status;
// Reinitialize the axis
status = masterMacsAxis::init();
if (status != asynSuccess) {
return status;
}
bool moving = false;
return forcedPoll(&moving);
}
/*
@@ -990,7 +993,7 @@ asynStatus masterMacsAxis::enable(bool on) {
if (switchedOn() == on) {
bool moving = false;
// Perform a poll to update the parameter library
poll(&moving);
forcedPoll(&moving);
return asynSuccess;
}
}