did not have enough counts
- Reduced polling frequency in emon
- Fixed a scriptcontext bug which would cause it to dump core in SctTransact
on interrupts
- Fixed an issue with missing <nl> at the end of batch files
- Added a feature which does not call halt when counting stops in hmcontrol.c
This is necessary for the BOA CCD
- Initalized doNotFree properly in hipadaba.c
- Added the travelling salesman reflection measurement algorithm
- Added another component to amorset
- Removed old SicsWait from nserver.c
- Added a means to nxscript to write 16 bit data for BOA
- Modified tasub to accept a drivabel as a motor and not only a motor.
This became necessary to make EIGER work as A2 on EIGER is a virtual
motor
- Added a warning for excessive data rates on monitors
- Added statistics to devser and thus to scriptcontext
- Added byte concatenation to dynstring
- Added aborting for reflection generation to fourmess.c
- Added data checksum testing to hipadaba, use for update tests
- Fixed interrupt discovery in network.c, caused invalid interrupt
codes which in turn confused sicscron which had to be fixed too.
- Renamed ubcalc into ubcalcint in order to reclaim the ubcalc for Jurg
- Added an a3offset to tasub in order to fix what I perceive an IS problem
- Added support for the newer version of the Siemens SPS, the S7
- Added a not yet fully working sinqhttpopt driver which talks to
http HM without libghttp
drivable. Required a new event in devexec.c
- Fixed the phytron driver to handle speed well
- Added a protocol driver for the TCP/IP bridge to the SLS magnets
- removed RemovePsiCommands (the choice if a command is removed or not
should be done when declaring it)
- reduced the include list to the necessary files
- poldizug now sends all codes all the time
- polterwrite writes the filename again
- sanswave has been modifed to support the new second generation velocity
selector
- sinqhttprot has been mdified to copy data to nodes, this for the second
generation HM object
- tasscan suppressed some output
a connection during an active run.
- Added an additional output mode for the connection in order to
support the batch run editor.
- Made clientput send everything with eWarning mode in order to support
the batch run editor.
- Added a better NetReadTillTerm
- Fixed a problem in synchronize.c
- Fixed an issue with reading empty line on normal connection sockets.
- Added a psi scan mode to mesure.c for TRICS
- Made motor print warnings when trying to reposition.
- Fixed abug in hkl.c which cause wrong signs.