a quite simple, but powerful state machine
There is not need to subclass StateMachine, but use an instance
of it. The code typically lives on methods of an other class.
Features:
- store any variables (except already defined attributes) on the state
- actions handle the conditions to stay or initiate a transition
by calling the state machines goto method
- a state machine might run endlessly or finish in a None action.
- it may be started or restarted
- a cleanup function for handling exceptions and for stop or restart
- support for time dependent features
Change-Id: I86b86ed1f25d04e305237edb99206912b068aedf
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27593
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
A common problematic practice is, to declare the value parameter
with the same FloatRange than the target. Because of measurement
errors, a value might be near, but outside the limit.
In order to avoid this, we force the programmer to declare a
bigger range for the value than for the target, or to
explicitly disable this check on a module property.
It is also fine to declare the value without limits.
This behavior may be disabled via command line option or in the
general config file. For simplicity, FloatRanges inside data
structures are not considered.
+ above command line option is also used to disable the error
handling on a string to float conversion
+ log appropriate error message for string to float conversion
Change-Id: Ib78ea1fb7c821442bf5847030573c8c27822dea5
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27574
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
a read method should not reply on the automatic conversion
of the return value from string to a number.
- transitional solution with generalConfig.lazy_numer_validation
+ changing slighly generalInit mechanism: for above feature
generalConfig.init is not required to be called (i.e. when
used on the client side)
Change-Id: Ibecce1a45669273c105932acdc0908de55bfd1b9
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27516
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
modules with a couple of parameters with similar read_* or
write_* methods may handle them by generic methods wrapped
with decorators ReadHandler / WriteHandler
The trinamic driver is included in this change for demonstrating
how it works.
In a further step, the special handling for the iohandler stuff can
be moved away from secop.server and secop.params, using this feature.
+ fix problem on startup of trinamic driver (needs MultiEvent.queue)
+ some other small fixes
+ apply recommended functools.wraps for wrapping
Change-Id: Ibfeff9209f53c47194628463466cee28366e17ac
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27460
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- bin/secop-server options -v and -q applied to console logger only
- level for logfile taken from general config
- option for automatic deletion of old logfiles
- added 'comlog' level (between debug and info)
This allows to run the servers by default with 'comlog' level on
the logfiles, which helps a lot for analyzing very rare communication
errors in retrospect.
to avoid spamming of the normal log files, comlog data is stored
separately, one file per communicator
+ redesign of remote logging (no more need of LoggerAdapter)
Change-Id: Ie156a202b1e7304e50bbe830901bc75872f6ffe2
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27427
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
this apllies only to the argument in frappy - in the case
of all members optional, they are put into the description,
not honouring issue 69
Change-Id: I8e9e4d9ef6bd5b9bb2748f3c6116b7094cd9e927
fix 2 problems:
- in case the window is smaller than the pollinterval, isAtTarget might be False
for up to the timeout delay
- in case the history is shorter than the window, and the ramp is fast enough to miss
any points during ramp, isAtTarget is True before the window time is reached.
This happens because the history is reset on write_target
+ do not wait when target is not changed (by more than precision)
tested!
Change-Id: Ia4ff4378fe91fa93be50168b2883a20b49ebfb6a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27159
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
- fix omit_unchanged
- names too short
+ other pylint complains
Change-Id: I3c277b461fad1a5fdf8e76ff1cc42b8742d1de16
Change-Id: I58fb64f91bcc2efef20df68f5c63a64315413286
- fix CommandType.__repr__
- secop/modules.py: command properties are allowed to be configured:
- section 2: remove comment and rename
- section 3: all accessible properties should be checked
- command description should be inherited also when taken from docstring
- move test for command inheritance to test_modules.py
- added tests to check for valid properties of commands
Change-Id: I5fd04e03be1faec5e54fed9735620bc5dc0f89c0
- fix CommandType.__repr__
- secop/modules.py: command properties are allowed to be configured:
- section 2: remove comment and rename
- section 3: all accessible properties should be checked
- command description should be inherited also when taken from docstring
- move test for command inheritance to test_modules.py
- added tests to check for valid properties of commands
Change-Id: Ic7795e305048625558e415ece099e6824df6e2c4
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/27135
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- asynconn: raise * from *
- asynconn: correct handling for timeout in AsynSerial
- add new py35compat
- target unit $
Change-Id: I052185ad3ebb3e3d1e3374f7ece9c7df06223951
Correct inheritance has to follow the MRO, not only consider
the direct base classes.
Patchset 3: changed only tests, indicating that we need to change the code
Following patchsets include a major change in params.py and
modules.py. The parameter properties for inheritance, corresponding
mainly to the constructor arguments have to be stored separately
from the property values including inherited stuff.
Change-Id: Ibcbccb6abcc22e7e2d91df8f70ef64226684d8cc
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/26805
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>