Compare commits
4 Commits
Author | SHA1 | Date | |
---|---|---|---|
2636296539 | |||
b09f081db9 | |||
af5d349254 | |||
d71c80fcb3 |
3
.gitmodules
vendored
Normal file
3
.gitmodules
vendored
Normal file
@ -0,0 +1,3 @@
|
||||
[submodule "turboPmac"]
|
||||
path = turboPmac
|
||||
url = https://gitea.psi.ch/lin-epics-modules/turboPmac
|
15
Makefile
15
Makefile
@ -12,9 +12,6 @@ REQUIRED+=motorBase
|
||||
# Specify the version of motorBase we want to build against
|
||||
motorBase_VERSION=7.2.2
|
||||
|
||||
# Specify the version of turboPmac we want to build against
|
||||
turboPmac_VERSION=0.13.0
|
||||
|
||||
# These headers allow to depend on this library for derived drivers.
|
||||
HEADERS += src/seleneGuideController.h
|
||||
HEADERS += src/seleneLiftAxis.h
|
||||
@ -22,15 +19,27 @@ HEADERS += src/seleneAngleAxis.h
|
||||
HEADERS += src/seleneOffsetAxis.h
|
||||
|
||||
# Source files to build
|
||||
SOURCES += turboPmac/sinqMotor/src/msgPrintControl.cpp
|
||||
SOURCES += turboPmac/sinqMotor/src/sinqAxis.cpp
|
||||
SOURCES += turboPmac/sinqMotor/src/sinqController.cpp
|
||||
SOURCES += turboPmac/src/pmacAsynIPPort.c
|
||||
SOURCES += turboPmac/src/turboPmacAxis.cpp
|
||||
SOURCES += turboPmac/src/turboPmacController.cpp
|
||||
SOURCES += turboPmac/src/pmacAsynIPPort.c
|
||||
SOURCES += src/seleneGuideController.cpp
|
||||
SOURCES += src/seleneLiftAxis.cpp
|
||||
SOURCES += src/seleneAngleAxis.cpp
|
||||
SOURCES += src/seleneOffsetAxis.cpp
|
||||
|
||||
# Store the record files
|
||||
TEMPLATES += turboPmac/sinqMotor/db/asynRecord.db
|
||||
TEMPLATES += turboPmac/sinqMotor/db/sinqMotor.db
|
||||
TEMPLATES += turboPmac/db/turboPmac.db
|
||||
TEMPLATES += db/seleneGuide.db
|
||||
|
||||
# This file registers the motor-specific functions in the IOC shell.
|
||||
DBDS += turboPmac/sinqMotor/src/sinqMotor.dbd
|
||||
DBDS += turboPmac/src/turboPmac.dbd
|
||||
DBDS += src/seleneGuide.dbd
|
||||
|
||||
USR_CFLAGS += -Wall -Wextra -Weffc++ -Wunused-result -Wextra -Werror # -Wpedantic // Does not work because EPICS macros trigger warnings
|
||||
|
@ -90,13 +90,13 @@ seleneVirtualAxes("$(NAME)", 1, 2, 3, 4, 5, 6, 9, 10);
|
||||
# Parametrize the EPICS record database with the substitution file named after the motor controller.
|
||||
# In order to provide the PVs for absolute position and normalization, the
|
||||
# corresponding `seleneGuide.db` file is loaded here as well.
|
||||
epicsEnvSet("SINQDBPATH","$(sinqMotor_DB)/sinqMotor.db")
|
||||
epicsEnvSet("SINQDBPATH","$(seleneGuide_DB)/sinqMotor.db")
|
||||
dbLoadTemplate("$(TOP)/motors/$(NAME).substitutions", "INSTR=$(INSTR)$(NAME):,CONTROLLER=$(NAME)")
|
||||
epicsEnvSet("SINQDBPATH","$(turboPmac_DB)/turboPmac.db")
|
||||
epicsEnvSet("SINQDBPATH","$(seleneGuide_DB)/turboPmac.db")
|
||||
dbLoadTemplate("$(TOP)/motors/$(NAME).substitutions", "INSTR=$(INSTR)$(NAME):,CONTROLLER=$(NAME)")
|
||||
epicsEnvSet("SINQDBPATH","$(seleneGuide_DB)/seleneGuide.db")
|
||||
dbLoadTemplate("$(TOP)/motors/$(NAME).substitutions", "INSTR=$(INSTR)$(NAME):,CONTROLLER=$(NAME)")
|
||||
dbLoadRecords("$(sinqMotor_DB)/asynRecord.db","P=$(INSTR)$(NAME),PORT=$(ASYN_PORT)")
|
||||
dbLoadRecords("$(seleneGuide_DB)/asynRecord.db","P=$(INSTR)$(NAME),PORT=$(ASYN_PORT)")
|
||||
```
|
||||
|
||||
### Substitution file
|
||||
|
@ -22,6 +22,20 @@ seleneAngleAxis::seleneAngleAxis(seleneGuideController *pController, int axisNo,
|
||||
pC_->paramLibAccessFailed(status, "motorCanDisable", axisNo_,
|
||||
__PRETTY_FUNCTION__, __LINE__);
|
||||
}
|
||||
|
||||
// Even though this happens already in sinqAxis, a default value for
|
||||
// motorMessageText is set here again, because apparently the sinqAxis
|
||||
// constructor is not run before the string is accessed?
|
||||
status = setStringParam(pC_->motorMessageText(), "");
|
||||
if (status != asynSuccess) {
|
||||
asynPrint(pC_->pasynUser(), ASYN_TRACE_ERROR,
|
||||
"Controller \"%s\", axis %d => %s, line %d:\nFATAL ERROR "
|
||||
"(setting a parameter value failed "
|
||||
"with %s)\n. Terminating IOC",
|
||||
pC_->portName, axisNo_, __PRETTY_FUNCTION__, __LINE__,
|
||||
pC_->stringifyAsynStatus(status));
|
||||
exit(-1);
|
||||
}
|
||||
}
|
||||
|
||||
asynStatus seleneAngleAxis::stop(double acceleration) {
|
||||
@ -59,7 +73,7 @@ asynStatus seleneAngleAxis::targetPosition(double *targetPosition) {
|
||||
|
||||
asynStatus seleneAngleAxis::doPoll(bool *moving) {
|
||||
|
||||
char userMessage[pC_->MAXBUF_] = {0};
|
||||
char errorMessage[pC_->MAXBUF_] = {0};
|
||||
|
||||
// In the doPoll method of `seleneLiftAxis`, the parameters
|
||||
// `motorStatusMoving` and `motorStatusDone` of this axis have already been
|
||||
@ -189,15 +203,15 @@ asynStatus seleneAngleAxis::doPoll(bool *moving) {
|
||||
// axis.
|
||||
pl_status =
|
||||
pC_->getStringParam(liftAxis_->axisNo(), pC_->motorMessageText(),
|
||||
sizeof(userMessage), userMessage);
|
||||
sizeof(errorMessage), errorMessage);
|
||||
if (pl_status != asynSuccess) {
|
||||
return pC_->paramLibAccessFailed(pl_status, "motorMessageText",
|
||||
liftAxis_->axisNo(),
|
||||
__PRETTY_FUNCTION__, __LINE__);
|
||||
}
|
||||
|
||||
if (strlen(userMessage) != 0) {
|
||||
pl_status = setStringParam(pC_->motorMessageText(), userMessage);
|
||||
if (strlen(errorMessage) != 0) {
|
||||
pl_status = setStringParam(pC_->motorMessageText(), errorMessage);
|
||||
if (pl_status != asynSuccess) {
|
||||
return pC_->paramLibAccessFailed(pl_status, "motorMessageText_",
|
||||
axisNo_, __PRETTY_FUNCTION__,
|
||||
|
@ -99,6 +99,20 @@ seleneLiftAxis::seleneLiftAxis(seleneGuideController *pC, int axis1No,
|
||||
pC_->paramLibAccessFailed(status, "motorCanDisable", axisNo_,
|
||||
__PRETTY_FUNCTION__, __LINE__);
|
||||
}
|
||||
|
||||
// Even though this happens already in sinqAxis, a default value for
|
||||
// motorMessageText is set here again, because apparently the sinqAxis
|
||||
// constructor is not run before the string is accessed?
|
||||
status = setStringParam(pC_->motorMessageText(), "");
|
||||
if (status != asynSuccess) {
|
||||
asynPrint(pC_->pasynUser(), ASYN_TRACE_ERROR,
|
||||
"Controller \"%s\", axis %d => %s, line %d:\nFATAL ERROR "
|
||||
"(setting a parameter value failed "
|
||||
"with %s)\n. Terminating IOC",
|
||||
pC_->portName, axisNo_, __PRETTY_FUNCTION__, __LINE__,
|
||||
pC_->stringifyAsynStatus(status));
|
||||
exit(-1);
|
||||
}
|
||||
}
|
||||
|
||||
asynStatus seleneLiftAxis::init() {
|
||||
@ -493,10 +507,6 @@ asynStatus seleneLiftAxis::startCombinedMove() {
|
||||
if (status != asynSuccess) {
|
||||
return status;
|
||||
}
|
||||
|
||||
errlogPrintf("Target lift: %lf, Target angle: %lf\n", liftTargetPosition,
|
||||
angleTargetPosition);
|
||||
|
||||
auto targetPositions =
|
||||
positionsFromLiftAndAngle(liftTargetPosition, angleTargetPosition);
|
||||
|
||||
@ -516,8 +526,6 @@ asynStatus seleneLiftAxis::startCombinedMove() {
|
||||
targetPositions[0], targetPositions[1], targetPositions[2],
|
||||
targetPositions[3], targetPositions[4], targetPositions[5]);
|
||||
|
||||
errlogPrintf("%s\n", command);
|
||||
|
||||
// No answer expected
|
||||
return pC_->writeRead(axisNo_, command, response, 0);
|
||||
}
|
||||
|
@ -80,6 +80,20 @@ seleneOffsetAxis::seleneOffsetAxis(seleneGuideController *pController,
|
||||
pC_->paramLibAccessFailed(status, "motorCanDisable", axisNo_,
|
||||
__PRETTY_FUNCTION__, __LINE__);
|
||||
}
|
||||
|
||||
// Even though this happens already in sinqAxis, a default value for
|
||||
// motorMessageText is set here again, because apparently the sinqAxis
|
||||
// constructor is not run before the string is accessed?
|
||||
status = setStringParam(pC_->motorMessageText(), "");
|
||||
if (status != asynSuccess) {
|
||||
asynPrint(pC_->pasynUser(), ASYN_TRACE_ERROR,
|
||||
"Controller \"%s\", axis %d => %s, line %d:\nFATAL ERROR "
|
||||
"(setting a parameter value failed "
|
||||
"with %s)\n. Terminating IOC",
|
||||
pC_->portName, axisNo_, __PRETTY_FUNCTION__, __LINE__,
|
||||
pC_->stringifyAsynStatus(status));
|
||||
exit(-1);
|
||||
}
|
||||
}
|
||||
|
||||
asynStatus seleneOffsetAxis::init() {
|
||||
@ -199,6 +213,12 @@ asynStatus seleneOffsetAxis::doPoll(bool *moving) {
|
||||
|
||||
// Update the parameter library
|
||||
if (error != 0) {
|
||||
status = setStringParam(pC_->motorMessageText(), userMessage);
|
||||
if (status != asynSuccess) {
|
||||
return pC_->paramLibAccessFailed(status, "motorMessageText",
|
||||
axisNo_, __PRETTY_FUNCTION__,
|
||||
__LINE__);
|
||||
}
|
||||
status = setIntegerParam(pC_->motorStatusProblem(), true);
|
||||
if (status != asynSuccess) {
|
||||
return pC_->paramLibAccessFailed(status, "motorStatusProblem_",
|
||||
|
1
turboPmac
Submodule
1
turboPmac
Submodule
Submodule turboPmac added at 75292a6a9c
Reference in New Issue
Block a user