@@ -7,12 +7,12 @@ Modbus/TCP communication, using Mark Rivers' modbus module
|
||||
## Supported Controller Models
|
||||
|
||||
The following ANF controller versions are supported:
|
||||
|
||||
```
|
||||
ANF1E: 1-axis stepper controller, modbus tcp/ip
|
||||
ANF1: 1-axis stepper controller, no network interface
|
||||
ANF2E: 2-axis stepper controller, modbus tcp/ip
|
||||
ANF2: 2-axis stepper controller, no network interface
|
||||
|
||||
```
|
||||
A stack of controller can contain up to 6 modules, one of
|
||||
which needs to have the ethernet option. A single-channel
|
||||
implementation would need the module with ethernet.
|
||||
@@ -30,7 +30,7 @@ requires the device to be configured for Modbus-TCP.
|
||||
## Controller Quirks
|
||||
|
||||
* The controller doesn't allow absolute moves when a limit is active;
|
||||
The only way to move a motor off of a limit is by jogging.
|
||||
The only way to move a motor off of a limit is by **jogging**.
|
||||
|
||||
* The base speed is set when an axis is configured. This driver corrects
|
||||
the acceleration sent by the motor record (VBAS isn't guaranteed to match
|
||||
@@ -58,9 +58,8 @@ The AMCI Net Configurator can be used to:
|
||||
|
||||
* Determine hex config strings for each axis
|
||||
|
||||
### Example hex configurations
|
||||
### Example axis configuration
|
||||
|
||||
The AMCI Net Configurator can be used to generate hex configurations. Here are some example:
|
||||
```
|
||||
0x86000000 - Step & Direction pulses, Diagnostic Feedback, No home switch, No limits
|
||||
0x86280000 - Step & Direction pulses, Diagnostic Feedback, No home switch, Active-low CW/CCW limits
|
||||
|
||||