config update
This commit is contained in:
1 parent
b2bdd3d4de
commit
b486e6cb5c
2 files changed
+215
-49
No files matched your search
@@ -90,21 +90,21 @@ foptx:
|
||||
connectionTimeout: 20
|
||||
userParameter:
|
||||
#120 micros, 60
|
||||
in: -13.890
|
||||
out: -14
|
||||
# in: -13.890
|
||||
# out: -14
|
||||
#150 micros, 60
|
||||
# in: -14.191
|
||||
# out: -13.831
|
||||
#170 micron, 60 nm
|
||||
#in: -13.8909
|
||||
#out: -13.831
|
||||
in: -13.8909
|
||||
out: -13.831
|
||||
#250 micron, 30 nm, Abe structures
|
||||
# in: -13.8809375
|
||||
# out: -14.1809
|
||||
#250 micron, 30 nm, Tomas structures
|
||||
# in: -14.5490625
|
||||
# out: -14.1809
|
||||
fzp_diameter: 120 # microns
|
||||
fzp_diameter: 170 # microns
|
||||
fzp_outermost_zone_width: 60 # nm
|
||||
detector_distance: 7196 # mm, sample-to-detector; unknown for now
|
||||
fzp_details: "manufacturing notes here" # free-text FZP manufacturing notes
|
||||
@@ -129,11 +129,11 @@ fopty:
|
||||
connectionTimeout: 20
|
||||
userParameter:
|
||||
#150 micron, 60
|
||||
in: 1.02
|
||||
out: 0.869
|
||||
# in: 1.02
|
||||
# out: 0.869
|
||||
#170 micron, 60 nm
|
||||
#in: 0.42
|
||||
#out: 0.57
|
||||
in: 0.42
|
||||
out: 0.57
|
||||
#250 micron, 30 nm, Abe structures
|
||||
# in: 2.8299
|
||||
# out: 2.8299
|
||||
@@ -371,17 +371,17 @@ fosax:
|
||||
connectionTimeout: 20
|
||||
userParameter:
|
||||
#120micron, 60 nm, 7.9 kev
|
||||
in: 8.74251
|
||||
out: 5.1
|
||||
# in: 8.74251
|
||||
# out: 5.1
|
||||
#150micron, 60 nm, 7.9 kev
|
||||
# in: 9.0393
|
||||
# out: 5.1
|
||||
#170 micron, 60 nm, 7.6 kev
|
||||
#in: 8.7568
|
||||
#out: 5.1
|
||||
# in: 8.7568
|
||||
# out: 5.1
|
||||
#170 micron, 60 nm, 7.9 kev
|
||||
#n: 8.722151
|
||||
#ut: 5.1
|
||||
in: 8.718233
|
||||
out: 5.1
|
||||
#250 micron, 30 nm, Abe structures
|
||||
# in: 8.7392
|
||||
# out: 5.1
|
||||
@@ -409,13 +409,13 @@ fosay:
|
||||
connectionTimeout: 20
|
||||
userParameter:
|
||||
#120 micron, 60 nm, 7.9 kev
|
||||
in: -0.645276
|
||||
# in: -0.645276
|
||||
#150 micron, 60 nm, 7.9 kev
|
||||
#in: -0.6422
|
||||
#170 micron, 60 nm, 7.6 kev
|
||||
#in: -0.0235
|
||||
#170 micron, 60 nm, 7.9 kev
|
||||
#in: -0.0563
|
||||
in: -0.062253
|
||||
#250 micron, 30 nm, Abe structures
|
||||
# in: -2.3684
|
||||
#250 micron, 30 nm, Tomas structures
|
||||
@@ -439,15 +439,15 @@ fosaz:
|
||||
readoutPriority: baseline
|
||||
connectionTimeout: 20
|
||||
userParameter:
|
||||
#150 micron, 60 nm, 7.9 kev, foptz 16.9, probe size 7.5 mu
|
||||
in: 11.0998
|
||||
out: 6
|
||||
#150 micron, 60 nm
|
||||
# in: 11.0998
|
||||
# out: 6
|
||||
#170 micron, 60 nm, 7.6 kev
|
||||
#in: 8.5
|
||||
#out: 6
|
||||
#170 micron, 60 nm, 7.9 kev, foptz 16.9, probe size 7.5 mu
|
||||
# in: 13.1
|
||||
# out: 6
|
||||
in: 14.1
|
||||
out: 6
|
||||
# micron, 30 nm, 7.9 kev, very close to the sample. make sure foptz is 32.02 or smaller //abe's fzp's
|
||||
# in: 0.5
|
||||
# out: -5
|
||||
@@ -703,30 +703,30 @@ calculated_signal:
|
||||
# deviceTags:
|
||||
# - ptycho_flomni
|
||||
|
||||
omny_panda_continuous:
|
||||
readoutPriority: async
|
||||
deviceClass: csaxs_bec.devices.panda_box.panda_box_omny.PandaBoxOMNY
|
||||
deviceConfig:
|
||||
host: omny-panda.psi.ch
|
||||
raw_stream_mode: true
|
||||
signal_alias:
|
||||
FMC_IN.VAL1.Value: cap_voltage_fzp_y
|
||||
FMC_IN.VAL2.Value: cap_voltage_fzp_x
|
||||
INENC1.VAL.Value: interf_st_fzp_y
|
||||
INENC2.VAL.Value: interf_st_fzp_x
|
||||
INENC3.VAL.Value: interf_st_rotz
|
||||
INENC4.VAL.Value: interf_st_rotx
|
||||
PCAP.GATE_DURATION.Value: pcap_gate_duration_value
|
||||
# TTLIN1 (detector trigger) feeds both blocks below - confirmed 2026-09-15 against the
|
||||
# omny-panda hardware, see docs/developer/panda_box_free_running_setup.md. PCAP.BITS0
|
||||
# is a shared 32-bit word; PandaBoxOMNY masks it to bit 0 (TTLIN1.VAL) before
|
||||
# publishing gate_detector_active. COUNTER1 counts TTLIN1's falling edge, i.e. one
|
||||
# increment per completed exposure; it also doubles as the on_complete signal. Confirmed
|
||||
# working end-to-end 2026-09-15; now under speed testing beyond the initial 100 Hz.
|
||||
PCAP.BITS0.Value: gate_detector_active
|
||||
COUNTER1.OUT.Value: frame_counter
|
||||
enabled: true
|
||||
readOnly: false
|
||||
softwareTrigger: false
|
||||
deviceTags:
|
||||
- ptycho_flomni
|
||||
# omny_panda_continuous:
|
||||
# readoutPriority: async
|
||||
# deviceClass: csaxs_bec.devices.panda_box.panda_box_omny.PandaBoxOMNY
|
||||
# deviceConfig:
|
||||
# host: omny-panda.psi.ch
|
||||
# raw_stream_mode: true
|
||||
# signal_alias:
|
||||
# FMC_IN.VAL1.Value: cap_voltage_fzp_y
|
||||
# FMC_IN.VAL2.Value: cap_voltage_fzp_x
|
||||
# INENC1.VAL.Value: interf_st_fzp_y
|
||||
# INENC2.VAL.Value: interf_st_fzp_x
|
||||
# INENC3.VAL.Value: interf_st_rotz
|
||||
# INENC4.VAL.Value: interf_st_rotx
|
||||
# PCAP.GATE_DURATION.Value: pcap_gate_duration_value
|
||||
# # TTLIN1 (detector trigger) feeds both blocks below - confirmed 2026-09-15 against the
|
||||
# # omny-panda hardware, see docs/developer/panda_box_free_running_setup.md. PCAP.BITS0
|
||||
# # is a shared 32-bit word; PandaBoxOMNY masks it to bit 0 (TTLIN1.VAL) before
|
||||
# # publishing gate_detector_active. COUNTER1 counts TTLIN1's falling edge, i.e. one
|
||||
# # increment per completed exposure; it also doubles as the on_complete signal. Confirmed
|
||||
# # working end-to-end 2026-09-15; now under speed testing beyond the initial 100 Hz.
|
||||
# PCAP.BITS0.Value: gate_detector_active
|
||||
# COUNTER1.OUT.Value: frame_counter
|
||||
# enabled: true
|
||||
# readOnly: false
|
||||
# softwareTrigger: false
|
||||
# deviceTags:
|
||||
# - ptycho_flomni
|
||||
@@ -0,0 +1,166 @@
|
||||
# Plan: improve the `fsamx` PID centering in `move_samx_to_scan_region`
|
||||
|
||||
Status: **DRAFT — NOT FINAL, NEEDS FURTHER DISCUSSION. Not implemented.**
|
||||
Written during live beamtime operation on request; no code changes made — see
|
||||
the conversation this plan came from. It rests on one day of logs
|
||||
(2026-09-18) and small samples (18 first-move cases, 25 later-iteration steps)
|
||||
and has not been tested on the instrument. The open questions at the bottom
|
||||
must be settled before any code is changed.
|
||||
|
||||
## Context
|
||||
|
||||
`RtFlomniController.move_samx_to_scan_region`
|
||||
(`csaxs_bec/devices/omny/rt/rt_flomni_ophyd.py`, ~lines 181-230) centres
|
||||
`fsamx` after the rt stage has moved to `cenx`. It reads the PID X voltage
|
||||
(`get_pid_x()`, `g` command on the rt controller, range ±10 V) and compares it
|
||||
with the expected voltage (`rtx` user parameter `rt_pid_voltage`, stored by
|
||||
`feedback_enable_with_reset`).
|
||||
|
||||
- If `|V - expected|` is below the start threshold: `No correction of fsamx needed`.
|
||||
- Otherwise loop until `|V - expected| < 1`, each iteration doing
|
||||
`pid_x_correction -= (V - expected) * 0.006` and moving `fsamx` to
|
||||
`fsamx_in + cenx/1000*0.7 + pid_x_correction`, then `laser_tracker_on()`.
|
||||
|
||||
**Trigger for this plan.** The start threshold was lowered from 2.0 V to 1.2 V
|
||||
(uncommitted edit in the production working tree when this was written) with
|
||||
the aim of reducing the target range below 0.05 V. Afterwards corrections rose
|
||||
from about 8.5 to about 49 per hour and the readings still swung by about
|
||||
±1-2 V.
|
||||
|
||||
**Data source.** `/var/log/bec/DeviceServer.log` and `ScanServer.log` on
|
||||
`x12sa-bec-001.psi.ch`, 2026-09-18 08:00-20:19. These logs are not part of the
|
||||
repo. The relevant log messages come from the `rt_flomni_ophyd` logger
|
||||
(`Current PID voltage`, `Moving fsamx to …, PID portion of that …`,
|
||||
`No correction of fsamx needed`, `No further correction needed`).
|
||||
|
||||
## Findings this plan rests on
|
||||
|
||||
1. **The loop gain is too small, not too large.** The measured stage response
|
||||
is 13.4 µm/V (rms 0.18 V over 25 steps at constant `cenx`), while the code
|
||||
uses `0.006` mm/V = 6 µm/V. Each step therefore removes only about 45 % of
|
||||
the error (measured contraction ×0.57, predicted ×0.55). Going from 1.2 V to
|
||||
below 0.05 V takes about 6 iterations, each followed by a laser tracker
|
||||
wait. At constant `cenx` the loop does not overshoot.
|
||||
2. **The first move of a sequence double counts.** It applies the `cenx`
|
||||
feed-forward jump (`0.7*Δcenx` since the last move, median 35 µm) and a
|
||||
correction increment `-0.006*(V-e)` computed from a reading that already
|
||||
contains that `cenx` lag. The sign of V flips after the first move in 12 of
|
||||
18 cases, e.g. V = -2.44 V with a +36.7 µm feed-forward jump and a +14.6 µm
|
||||
correction step gives V = +1.82 V. A two-term fit suggests the true
|
||||
feed-forward factor is nearer 0.8 than 0.7 (weak evidence, n = 18).
|
||||
3. **Blind steps at the rail overshoot.** In four cases (12:25, 13:56, 18:42,
|
||||
19:04) a scan stop was followed by a reading pinned at -10.0 V. The loop
|
||||
then made three fixed +60 µm moves (`0.006 * 10 V`), the reading flipped to
|
||||
+10.0 V, and the laser tracker waited 37-100 s for the target. Twice the
|
||||
wait exceeded 100 polls and raised
|
||||
`RtError: Failed to reach laser target position`.
|
||||
4. **`pid_x_correction` is lost on reload.** After the 19:30 device reload it
|
||||
restarted from 0 (first PID part -0.009), while `fsamx` itself stayed where
|
||||
it was.
|
||||
5. **About 1 V of scan-to-scan alternation is unexplained.** Consecutive scan
|
||||
points alternate high/low with a period of about 46 s. It was present all
|
||||
day, including before the threshold change (08:00-08:30, 10:00-16:00). The
|
||||
`cenx` and last-`fsamx`-position model leaves a residual of about 1 V
|
||||
(R² 0.67 before 19:30, 0.30 after 19:36). This is a rotation-tomography
|
||||
run: every scan point is a new `angle` and `cenx` follows it.
|
||||
6. **The `Expected PID voltage` log line is commented out**
|
||||
(`rt_flomni_ophyd.py:196`). The expected value only appears once per
|
||||
restart as `Using PID voltage from rtx user parameter`.
|
||||
|
||||
## The math
|
||||
|
||||
Notation: `V` = PID voltage, `e` = expected voltage, `s` = stage response
|
||||
(mm/V), `x` = `fsamx` position relative to `fsamx_in` (mm), `c` = `cenx`.
|
||||
|
||||
Plant (fits the in-loop data to 0.18 V rms):
|
||||
|
||||
```
|
||||
V - e = (x - x*(c)) / s, x*(c) = 0.7*c/1000 + drift, s ≈ 0.0134 mm/V
|
||||
```
|
||||
|
||||
Current step: `Δx = -0.006 * (V - e)`, i.e. gain `g = 0.006` and per-step error
|
||||
ratio `r = 1 - g/s ≈ 0.55`. To reach a residual `ε` from `V0` needs
|
||||
`n = ln(ε/V0) / ln(r)` steps: 6 steps for 1.2 V → 0.05 V.
|
||||
|
||||
Proposed step (Newton, damped): `Δx = -DAMP * s * (V - e)` with
|
||||
`DAMP ≈ 0.85`. With a 15 % gain error the ratio is about 0.15, so 1.5 V → 0.03 V
|
||||
in two iterations. `s` may be adapted from the last two iterations
|
||||
(`s_est = Δx_prev / (V_prev - V_now)`), clamped to 8-20 µm/V.
|
||||
|
||||
Double counting: on the first move `V - e` already contains `-(0.7*(c - c_prev)/1000)/s`,
|
||||
which the feed-forward jump removes. Adding `-0.006*(V-e)` on top overshoots.
|
||||
|
||||
## Proposed changes (all in `move_samx_to_scan_region`)
|
||||
|
||||
1. **Newton step** as above instead of the fixed small gain.
|
||||
2. **Remove the double counting.**
|
||||
- **Option A (preferred):** compute the target from the actual position,
|
||||
`x_target = x_now - DAMP*s*(V-e)`, and store
|
||||
`pid_x_correction = x_target - 0.7*cenx/1000`, so the `cenx` lag is never
|
||||
accumulated as drift.
|
||||
- **Option B:** apply the feed-forward move first, re-read V, then correct.
|
||||
Simpler, but costs about 1 s plus a tracker wait per correction.
|
||||
3. **Derive `x_now` from the `fsamx` readback** instead of a running sum, so a
|
||||
reload does not reset the bookkeeping.
|
||||
4. **Clamp steps at the rail.** When `|V| >= 9.9`, cap the step at about 30 µm
|
||||
and re-read instead of making blind ±60 µm steps.
|
||||
5. **Hysteresis.** Start about 0.5 V, stop about 0.15 V (currently start 1.2 V,
|
||||
stop 1.0 V, so the next `cenx` step re-triggers immediately).
|
||||
6. **Logging.**
|
||||
- Restore the `Expected PID voltage` line next to each `Current PID voltage`.
|
||||
- Log `angle`, `cenx`, V and the `fsamx` readback per scan point.
|
||||
- Log `laser_tracker_show_all()` output when `laser_tracker_wait_on_target`
|
||||
times out (the tracker's beam position, target and piezo state are not
|
||||
logged today).
|
||||
|
||||
Sketch (not tested):
|
||||
|
||||
```python
|
||||
S, DAMP, FF, VCLIP = 0.0134, 0.85, 0.7e-3, 8.0 # mm/V, -, mm per cenx unit, V
|
||||
x_now = fsamx.obj.readback.get() - fsamx_in # actual position (mm)
|
||||
for _ in range(MAX_ITER):
|
||||
v = self.get_pid_x() - expected_voltage
|
||||
if abs(v) < V_STOP:
|
||||
break
|
||||
x_now -= DAMP * S * np.clip(v, -VCLIP, VCLIP)
|
||||
fsamx.obj.pid_x_correction = x_now - FF * cenx # drift not explained by cenx
|
||||
fsamx.obj.move(fsamx_in + x_now, wait=True)
|
||||
time.sleep(0.1)
|
||||
self.laser_tracker_on()
|
||||
```
|
||||
|
||||
## What this will not fix
|
||||
|
||||
The unexplained ~1 V scan-to-scan alternation (finding 5) is not addressed. A
|
||||
0.05 V threshold would chase it with a move on nearly every scan point, and each
|
||||
move costs a laser tracker wait. The plan therefore assumes about 0.15 V as the
|
||||
stop level until the alternation is understood.
|
||||
|
||||
## Verification (once approved)
|
||||
|
||||
- **Offline replay:** run the proposed step logic against the logged
|
||||
(V, `cenx`, position) sequences from 2026-09-18 and compare iterations per
|
||||
correction and residual V with what happened.
|
||||
- **Bench check:** on the instrument, force a known offset of about 2 V and
|
||||
confirm convergence to below 0.15 V in at most 3 iterations with no sign
|
||||
flip; repeat with about 5 V.
|
||||
- **Rail case:** stop and restart a scan mid-way and confirm no ±10 V
|
||||
overshoot and no tracker timeout.
|
||||
- **Rate check:** confirm corrections per hour do not rise above the
|
||||
8.5/hour baseline.
|
||||
- **Unit tests:** the step function should be a pure function so it can be
|
||||
tested without hardware (see `tests/tests_devices`).
|
||||
|
||||
## Open questions for discussion
|
||||
|
||||
1. Is a threshold of 0.05 V realistic while the alternation is unexplained? The
|
||||
plan assumes about 0.15 V for the stop level.
|
||||
2. What is the true feed-forward factor: 0.7 (code) or about 0.8 (fit)?
|
||||
3. Option A or B for the double counting?
|
||||
4. Should the alternation be diagnosed first (angle dependence, backlash, the
|
||||
`v0`/`v1` FZP feedback toggle) before any code change?
|
||||
5. Is the 13.4 µm/V response stable across days? Only 2026-09-18 was analysed;
|
||||
the rotated logs from 2026-09-11 to 2026-09-17 could be checked.
|
||||
6. Should the already-made 1.2 V threshold change be kept, reverted, or left
|
||||
until this is settled? It is currently uncommitted in the production working
|
||||
tree.
|
||||