The stills distance is found from the data, so the --detector-distance pins go. Ice-ring detection,
the polarisation degree on one Rayonix set, the geometry pre-pass switch-off and the Alvra/one AGIPD
gains are no longer given: each was neutral or better without it. Kept: --wavelength where the file
states none or a different one, the polarisation on the mixed-form set (its beam-stop mask depends on
it) and the gain of one AGIPD set whose frames carry an uncorrected baseline.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_015CeEGgpKdfkCTJb3YNMJcu