694e687fcefbd7819cd6dd1aa6679bd6f44854b5
Section 1.1 called (x_beam, y_beam) the direct-beam position while constructing it as the point of normal incidence; on a tilted detector the two differ by D*tan(tilt), and a reader loading a header direct beam into it would be wrong by several pixels. Name it as the PONI (the system-wide convention, DETECTOR_GEOMETRY.md), say which point the construction pins, and state the laboratory frame's axes and handedness, which the rotation-sign, R-centring and Bijvoet-hand discussions all silently depended on. Two-theta is computed as a two-argument arctangent; say so. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01EFEJG6WBQv8th4UJFNe53N
Jungfraujoch
Application to receive data from the PSI JUNGFRAU and EIGER detectors.
All documentation is now placed in docs/ subdirectory and for the current version hosted on Jungfraujoch Read The Docs page.
Description
Jungfraujoch Data Acquisition System, Rugnux Data Processing Application, and Diffraction Viewer