The paragraph introduced with the two new report keys said an incomplete cusp could be "attributed to the mounting or cleared of it". The first half holds; the second does not. A symmetry axis within theta_max of PERPENDICULAR to the spindle carries the blind cone onto its opposite lobe, which a sweep leaves equally unmeasured, so a large angle is not on its own evidence that the mounting was harmless - and the key reports only the nearest axis. Also record the two keys in the changelog, and correct REPORT_VERSION there: the entry still said 6 after the bump to 7. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01EFEJG6WBQv8th4UJFNe53N