Running Rugnux gains a "Small-molecule data" section: what the default run does about short axes, wide and split spots, sparse patterns, overloads and glide / centre-of-symmetry space groups, the two settings worth checking (polarization on a laboratory source, the resolution cut), and what the unmerged HKLF 4 file holds. Rugnux with other programs gains a worked SHELXT -> SHELXL route (instruction file built from the report keys, what SHELXL does with the unmerged file). The SHELXT/SHELXL commands were run on a battery set's output to check they work as written. The quick start's file list now includes <prefix>_detector.jpg, which every default rotation run writes. Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01K5K8jvPPbmCrbqnWkddTuB