Tell: logger.debug stateements to see waht wait_ready does. Seems to not work. keeping for now until we fix.

This commit is contained in:
appleb_m committed 2025-12-22 13:53:03 +01:00
1 parent 10d378f0d1
commit 3c81d02814
2 files changed
+15 -1

No files matched your search

+4
View File
@@ -1,3 +1,7 @@
0.2.69
- check beamline state before running raster, rotation and automation
- lowered polling rate of daq status to improve GUI performance
- robot drys then parks after repeated mount failures
0.2.68:
- added check box to numberlineedits to switch between user input and spreadsheet
- re-enabled MLprediction
@@ -5,7 +5,7 @@ from PySide6.QtWidgets import QLabel, QComboBox, QPushButton, QMessageBox
from aaredaqlib.diffraction_geometry import DiffractionGeometry
from aaredaqlib.logger_config import setup_logger
from aaredaqlib.models import DAQStatusModel
from aaredaqlib.models import DAQStatusModel, BeamlineStateEnum
from aaredaqlib.rotation_scan import RotationScanRequest
from aaregui.panels.scan_settings_panel import ScanSettingsPanel
from aaregui.widgets.number_line_edit import NumberLineEdit, CheckedLineEdit
@@ -33,6 +33,7 @@ class RotationDataCollectionPanel(ScanSettingsPanel):
default_dtz=default_dtz,
default_transmission=default_transmission)
self.__beamline_state = None
self.__curr_pgroup = "p11206"
self._filename = ""
self._previous_sample_was_none_rotation = True
@@ -127,6 +128,10 @@ class RotationDataCollectionPanel(ScanSettingsPanel):
@Slot()
def run_screening(self):
if self.__beamline_state != BeamlineStateEnum.SampleAlignment:
logger.error(f"Beamline state {self.__beamline_state} is not Sample Alignment")
QMessageBox.critical(None, "Error", "Beamline state is not Sample Alignment")
return
if not self.check_before_run(scan_kind = "screening"):
logger.error("Cannot run measurement because of check")
return
@@ -146,6 +151,10 @@ class RotationDataCollectionPanel(ScanSettingsPanel):
@Slot()
def run_measurement(self):
if self.__beamline_state != BeamlineStateEnum.SampleAlignment:
logger.error(f"Beamline state {self.__beamline_state} is not Sample Alignment")
QMessageBox.critical(None, "Error", "Beamline state is not Sample Alignment")
return
if not self.check_before_run(scan_kind = "rotation"):
logger.error("Cannot run measurement because of check")
return
@@ -227,6 +236,7 @@ class RotationDataCollectionPanel(ScanSettingsPanel):
self.__dose_mgy = (time * s.bl.flux_ph_s * self._transmission) / (beam_area * kdose)
self.dose.setText(f"{(self.__dose_mgy / 1e6):.1f}")
self.__beamline_state = s.state
@Slot()
def update_omega_start(self):