@@ -73,7 +73,7 @@ The interface is working and communication to can slave are possible.
#### Disconnect Kvaser Leaf Light v2 USB
Seems to be something wrong when disconnecting/deregistering the USB:
The following errors will appear in dmesg if unplugging the device while link is up.
```
# Disconnecting leaf from usb:
[Mar24 10:31] usb 1-2: USB disconnect, device number 8
@@ -81,7 +81,9 @@ Seems to be something wrong when disconnecting/deregistering the USB:
[ +0.000002] kvaser_usb 1-2:1.0 can0: Cannot reset card, error -19
[ +0.000002] kvaser_usb 1-2:1.0 can0: Cannot stop device, error -19
```
Need to look into why.. Have contacted Kvaser support.
Checked with kvaser support and this is normal when unplugging the usb when the the link is up. So this is not an Issue.