diff --git a/kvaser/readme.md b/kvaser/readme.md index a38e002..507502b 100644 --- a/kvaser/readme.md +++ b/kvaser/readme.md @@ -73,7 +73,7 @@ The interface is working and communication to can slave are possible. #### Disconnect Kvaser Leaf Light v2 USB -Seems to be something wrong when disconnecting/deregistering the USB: +The following errors will appear in dmesg if unplugging the device while link is up. ``` # Disconnecting leaf from usb: [Mar24 10:31] usb 1-2: USB disconnect, device number 8 @@ -81,7 +81,9 @@ Seems to be something wrong when disconnecting/deregistering the USB: [ +0.000002] kvaser_usb 1-2:1.0 can0: Cannot reset card, error -19 [ +0.000002] kvaser_usb 1-2:1.0 can0: Cannot stop device, error -19 ``` -Need to look into why.. Have contacted Kvaser support. + +Checked with kvaser support and this is normal when unplugging the usb when the the link is up. So this is not an Issue. + ### More info