When the io of one SECoP module fails, it takes ages to startup
because each parameter poll takes the time to wait for a timeout.
After the first communication error on an io, no more startup polls
are tried on the modules using this io.
Change-Id: I0d250953dfe91a7d68d2d2b108395cc25d471afe
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28588
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
accept all sequences instead of just tuple / list
+ change Module.announceUpdate to convert value before
comparing with previous one (comparing will not work with numpy arrays)
Change-Id: I5eceef4297607107e2dde688af2833d3651a8775
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28525
Tested-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
revert basically the former change
"init generalConfig.defaults only in secop-server"
The problem of import order when setting generalConfig.defaults
has to be solved by not overriding already existing keys when
setting the default.
Change-Id: I82121e346607dd74146279c4241e13ab63c14096
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28011
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- SECoP modules are accessible as objects in the main python module
- parameters are accessed as attributes of these objects
- __repr__ is used for listing all parameters
- __call__ is used for 'change target and wait until no more busy'
typically used from a python interpreter or in a jupyter notebook
Change-Id: Idb55684eeff6d1262e5d1517a3ff934f1c1bf208
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28980
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- use update_switch_heater instead of write_switch_heater
for detecting switch time
- switch_time split into switch_on_time/switch_off_time
Change-Id: Id90a8b2c2520e24f3ee4a34aee25d41210e5d6d4