when the unit of parameter 'value' is taken from tango, the
'$' units of other parameters are already replaced by the configured
value and are not updated. this change fixes this.
not yet tested on entangle, but a test with similar code works
Change-Id: I87ad112b0965b39bb204d6c3d1fc1de6d4e14f60
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/29357
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
attached io in HasIO must not be mandatory - either uri or io
has to be given
Change-Id: Id39e40f98020d4051c1ad8105f6af6018aafaea8
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/29349
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
for easier configuration of multiple servers on the same machine,
FRAPPY_* env. variables are overriding the values from the
general config file
+ apply expanduser where approporiate
Change-Id: Icb73543402f5fb1b8a248a8b8d7fb470971492f4
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/29351
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
when the status of the rawsensor is not changed, the
status of the calibrated module was not initialized
properly.
Change-Id: I2c23e245226ffb7643060e486c9dfde250a79ce9
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/29356
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- SECoP modules are accessible as objects in the main python module
- parameters are accessed as attributes of these objects
- __repr__ is used for listing all parameters
- __call__ is used for 'change target and wait until no more busy'
typically used from a python interpreter or in a jupyter notebook
Change-Id: Idb55684eeff6d1262e5d1517a3ff934f1c1bf208
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28980
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
When the io of one SECoP module fails, it takes ages to startup
because each parameter poll takes the time to wait for a timeout.
After the first communication error on an io, no more startup polls
are tried on the modules using this io.
Change-Id: I0d250953dfe91a7d68d2d2b108395cc25d471afe
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28588
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
as all code using IO handlers has been changed to use
secop.rwhandler, IO handlers can be removed
Change-Id: Id57fbc4ce2744dbe73bb8792fd45449373f76bb5
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28526
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
accept all sequences instead of just tuple / list
+ change Module.announceUpdate to convert value before
comparing with previous one (comparing will not work with numpy arrays)
Change-Id: I5eceef4297607107e2dde688af2833d3651a8775
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28525
Tested-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
implement features including two proposed features
HasOffset and HasLimits
Change-Id: I7949f12dc8abe28fb2ee040e64e7db19d1b23b9a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28485
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- add a general channel switcher module
- change ls370res code from IOHandler to rwhandlers
+ fix an issue with the poller when io module is placed below
using modules in cfg file
after this, IOHandler stuff may be removed from Frappy
Change-Id: I787101fc1e365ae3e0453bfe59291e2011a1fe53
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28512
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
when a full path is given as single argument to secop-server,
the server name has to be sanitized
Change-Id: I1d11f076157548e90877f380f0cab3a6a3f96784
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28232
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- temperature (incl. heater)
- pressure (incl. control via valve motor)
- LHe and LN2 levels
not yet included: magnet power supply
Change-Id: Id4ee8f9b7ebfa6284e519ba485217f9a19d70d59
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28028
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- repeated errors on poller are only once logged (per poll
function / read_* method)
- during exception handling, silent=True on a SECoP error indicates
that the error is already logged
+ fix the name of HardwareError
+ add test for consistency of SECoPErrors
+ catch socket.timeout in AsynTcp
Change-Id: I9df6c775cc19553b22a4d6e39591092adf7ff9a1
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28139
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
in secop.proxy the callers modules method announceUpdate is
called from an other thread while the accessLock is locked,
creating a deadlock. solve this by creating an other lock
'updateLock' for the update.
+ add status parameter even to non-Readable proxy modules,
in order to indicate a failed connection
+ fix an error in secop_psi/softcal.py
Change-Id: Iae7c6d5a74001150a47aa9dc99209c15d972cd5e
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28130
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Implement LogfileHandler.getChild. This is needed to inherit
the configured level from the parent handler.
+ remove redundant assignmet of logfile_handler.max_days
Change-Id: I7277c28221bbb6108d75f2437634e9db9bf6761e
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28140
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- safe_current: current limit for unlimited move
- move_limit: max. angle to move with high current > safe_current
- direct axis parameter access is not exported by default
- support for home switch
- allow use without encoder
- automatic reset for motors in a configuration, where the motor
current is deliberatly low for a limited torque
- improved error message on driving failures
Change-Id: I25f8516905a2c4c3cda09d091d5a43004ec6dc6f
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28029
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
This valve needs 8 turns to open. As the encoder forgets
the number if turns on power cycle, a home switch is
mounte, which engages during the last turn when closing.
The final close position is determined by closing the valve
with a defined motor current/torque.
+ fix an issue in StateMachine.start: the first cycle
must be called after the new state is assigned
Change-Id: I34cd05d10d97b043f9e3126310943b74ee727382
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28030
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
When several poller threads are using the same io, the resposivity
of client requests is reduced, as every thread first finishes
its pending communication requests, before it is the turn of the
request thread. This is solved by using one common poller thread
for all modules sharing the same communicator.
+ fix an issue with overriding a property with a parameter, as
this is the case for pollperiod (cfg was applied to property
instead of overriding parameter)
+ separate setFastPoll arguments into flag and fast interval
+ fix missing announceUpdate call when read function fails
+ fix mechanism for triggering polls after an io connection
reconnected again.
Change-Id: I1115a61fae3de80d18416e61f40b52a0eebb637c
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28021
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>