- for the case when the remote module name does not match,
'read', 'change' and 'do' does not work
- a proxy to an IO class has enablePoll == False, but it needs
a triggerPoll for modules relying on it to work
- a proxy on a communicator module has a status even when the
remote does not - this needs 2 fixes
Change-Id: Icd44da4c2984f27ce7147dec633739f9176012ec
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/33168
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
for the use case where a parameter is a selection of discrete
float parameters
declaring a parameter as FloatEnumParam will create effectively
two parameters, one with datatype FloatRange and another with
datatype Enum, influencing each other automatically.
in a later change StructParam should be moved from
frappy/structparam.py to frappy/extparams.py
Change-Id: Ica3fd8dcaf6e9439e8178390f220dec15e52cc86
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32975
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Transported values in a change must be converted first.
As this is only relevant for the exotic "scaled" and "blob"
datatypes, this was not detected yet.
- add tests
- suppress warning PytestUnhandledThreadExceptionWarning in tests
+ change import_value methods to raise no other exceptions than
WrongTypeError and RangeError
+ simplify Command.do: as import_value already raises the
appropriate error, no more try/except is needed
Change-Id: I299e511468dc0fcecff4c20cf8a917da38b70786
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32743
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- StringIO.writeline sends a command and does not expect a reply
- StringIO.multicomm and BytesIO.multicomm is improved in order
to insert individual delays in between lines and individual
noreply flags
+ fix a bug in tutorial_t_control
+ improve readability of frappy.lib.classdoc.indent_description
Change-Id: I9dea113e19147684ec41aca5267a79816bbf202c
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32267
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
latexpdf fails with error message "Too deply nested".
We want to avoid reducing the nesting level of doc strings
in frappy.lib.classdoc (less nice output) or a level of
nesting in method doc strings.
- latex removed from Jenkinsfile
- added support for rst2pdf
Change-Id: Ieb3355ef506e636e7e43a726c68327e3b1154469
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32406
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Split module handling code from the dispatcher.
The new class for managing Modules is called SecNode.
* change logging to no longer need a reference to modobj
* modules get a reference to the secnode obj instead of the
dispatcher
* intermediate usage fixes for frappy_psi/sea
Change-Id: Ifee4bb47aa7a4508bb4a47c9a5873b7e2d5faf67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32249
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
previously, the signal handler would ignore SIGINTs and SIGTERMs during
server startup, so if there would be e.g. non-respoinding hardware, the
program could not be exited until a timeout occured.
For now, the default signal handler will be called. Later, we should
consider cleaning up the partial started modules.
Change-Id: I5bb802b5d996bb03dfa2679c1497e298fde1dd17
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32247
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
An attached property may be defined with mandatory=False.
In this case, when no value or an empty string is given,
<modobj>.<attached_mod> must return None after initialisation.
+ remove 'dispatcher' level from the logger hierarchy on modules
Change-Id: Icee3ae3f9142cd7a910c579ae1ffaa35f93cee03
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32187
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
For the case when the readback of a parameter does not reflect the
change immediately.
May also be used on Writable.target or Drivable.target with a short
BUSY period.
+ bug fix in an error message in frappy.datatypes.IntRange
Change-Id: I5e1c871629f9e3940ae80f35cb6307f404202b4a
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31981
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in SecopClient.disconnect joinng the reconnect thread may take
up to 10 s, because of the time.sleep(10) call in the reconnect
thread.
change the _shutdown attribute from bool to an Event, and
use Event.wait instead of time.sleep
Change-Id: Icea6a14ad73df0b3d26ef45806f4c05e6bf18492
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32137
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in the previous version FloatRange(max=100) was neither working
properly nor complaining, because the maxval=None default was
overriding the value for max.
possible fixes:
- raise an error when min/max used as argument (confusing for
the programmer, as it is a property)
- allow both versions minval/maxval and min/max (more code)
- use min/max and a pylint directive here (the only thing to
take care is not to use the min/max builtin in __init__)
this change uses the last option for the fix
Change-Id: Iff0e0c4d0d7b165003bdeffa67a93a1cd7f29eea
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31982
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
reading back the target does not work properly, because
a) the readback value might be delayed
b) there is no command to read back the target, SETP?1
is returning the working setpoint, which might be distinct
in case of a ramp
Change-Id: I0da2dbfc1a8ddbecbae6d0456ff64e008bc56336
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31983
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>