- send a heartbeat, if no events for 5 sec.
an interrupted connection (not closed by the other end) may
not be detected for a long time when nothing is sent
+ make the error reply on a non SECoPEror more verbose
e.g. "KeyError('foo')" instead of just "foo"
+ allow cfg file without nodeinterface
+ shorter logger name in HasIodev
Change-Id: I6b1ff23f9bf8c96feb25af44935596437b7d726f
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23098
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
config file format change:
The section names no longer contain a space, the are either
bare module names or 'NODE' or 'INTERFACE' (capitalized in order to
distingish from module names).
The present code still accepts the old form.
Moving to the 'toml' format was considered too, but this needs some
more investigations. The necessary code changes would be limited
to the method Server.loadCfgFile.
Change-Id: I6020058c9dcc4c1cbf38f5b9e8f67e9aad670183
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/23031
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
in case a remote is disconnected and can be reconnected quickly,
a seamless routing is possible. However, when after reconnection
the description has changed, the server is restarted.
+ more information in error messages from dispatcher
Change-Id: I0837e0254aee3d12a26481f6fd697081a53aabba
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/22506
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
modules using the old poller (now called secop.poller.BasicPoller)
need to explcitly declare it (pollerClass = BasicPoller)
BasicPoller is still used in:
secop_mlz/amagnet.py
secop_mlz/entangle.py
secop/simulation.py
Remark: before removing BasicPoller we may need a replacement for
Readable.pollParams
Change-Id: If1ae8b68e02f13e601334656b818337c882e06cc
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21910
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- None <= 0 is invalid in py3
- restrict BLOBType to bytes (may be changed after migration to py3)
- remove long
- use list(<dict>.items()) when dict is changed within loop
- allow initialization of properties in HasProperties without
supercall to base class
- <dict>.values() can not be indexed
- adapted/removed various tests. additional tests might be added
after definitive migration to py3
after this change, all the tests run with py3, also secop-server and
secop-gui were tested with an example, but other code might still contain
py3 incompatibilities
Change-Id: I881c6972aeabb8494a21a6cbc7ffeddfd4f5d4f8
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21306
Tested-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Bjoern Pedersen <bjoern.pedersen@frm2.tum.de>
the poller is now a separate (python-)module
- 3 categories of polled parameters:
- regular
- dynamic: accelerated when module is busy
- slow: less frequent, with lower priority
- several modules might share a poller. this makes sense, when a
they share a common communicator
- modules using the new poller must define pollerClass
- pollerClass may be define even an other poller implementation
- the old simple poller is still used on Readables without pollerClass
- the poller can not be configured in the config file only, as the
poll attributes have special values for this poller
Change-Id: Ifd811beeb45733bcbf801608ade877a3a601c24a
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/21066
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
for easier distinction:
- camelCase or singleword: framework method
- snake_case: driver method
(driver) parameters are lowercase, single word framework variables may
have to start with uppercase letters to distinguish...
Change-Id: I76536b6390324625b242c4f190553014c2ca61d6
Reviewed-on: https://forge.frm2.tum.de/review/20295
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
initialisation occurs in this order:
- object creeation (via __init__ which should consume the cfg values it knows about)
- registering each object with the dispatcher
- calling init_module() on each module (for connecting to other modules, checking hw, creating threads....)
- calling start_module(cb) on each module. after the module finished startup it should call cb(self) once.
This is the right place to do initialisation of hw which is not needed to read from the hw.
(uploading curves, polling/re-setting all parameters, etc.)
Change-Id: Ieaf9df5876e764634836861241f58ab986027f44
Reviewed-on: https://forge.frm2.tum.de/review/18566
Tested-by: JenkinsCodeReview <bjoern_pedersen@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>