Added support for the AMOR SPS-S5 using streamdevice

This commit is contained in:
2016-08-04 14:38:50 +02:00
parent 7c1693e606
commit 28999f2212
3 changed files with 91 additions and 0 deletions

34
iocBoot/iocsinqEPICS/stsps.cmd Executable file
View File

@ -0,0 +1,34 @@
#!../../bin/centos7-x86_64/sinqEPICS
# for debugging..................
## You may have to change sinqEPICS to something else
## everywhere it appears in this file
< envPaths
cd ${TOP}
## Register all support components
dbLoadDatabase "dbd/sinqEPICS.dbd"
dbLoadDatabase "dbd/sinq.dbd"
sinqEPICS_registerRecordDeviceDriver pdbbase
## Load record instances
#dbLoadRecords("db/xxx.db","user=koenneckeHost")
#---------- Install SPS
drvAsynIPPortConfigure("spss5", "localhost:63000",0,0,0)
#drvAsynIPPortConfigure("slsvme", "localhost:8080",0,0,0)
dbLoadRecords("$(ASYN)/db/asynRecord.db","P=SQ:AMOR:,R=spss5,PORT=spss5,ADDR=0,OMAX=80,IMAX=80")
epicsEnvSet ("STREAM_PROTOCOL_PATH", "$(TOP)/sinqEPICSApp/Db:.")
cd ${TOP}/iocBoot/iocsinqEPICS
dbLoadRecords("$(TOP)/sinqEPICSApp/Db/spsamor.db","PREFIX=SQ:AMOR:SPSS5:")
iocInit
## Start any sequence programs
#seq sncxxx,"user=koenneckeHost"

View File

@ -0,0 +1,32 @@
# DB definition for a SPS-S5 with the custom RS232 interface as used at SINQ.
#The digital inputs. Ignore the first one, which is the response character R
record(waveform, "$(PREFIX)DigitalInput") {
field(DTYP, "stream")
field(INP, "@spss5.proto readDigital() spss5 0")
field(SCAN, "5 second")
field(NELM, "16")
field(FTVL, "LONG")
field(PREC, "1")
}
# The analog inputs, again ignore the first one as it is the response character A
record(waveform, "$(PREFIX)AnalogInput") {
field(DTYP, "stream")
field(INP, "@spss5.proto readAnalog() spss5 0")
field(SCAN, "5 second")
field(NELM, "8")
field(FTVL, "LONG")
field(PREC, "1")
}
# This is forwarding the S0001 style strings to the hardware. This is the easiest solution but requires
# Hardware knowledge upstream. Which is required anyway. The syntax is: SBBBI with 3 characters for the byte
# to set and one character for the bit in the byte. The Byte must always be filled with 0 to the left.
record(stringout, "$(PREFIX)Push") {
field(DESC, "String for pushing buttons")
field(DTYP, "stream")
field(OUT, "@spss5.proto push() spss5 0")
}

View File

@ -0,0 +1,25 @@
# Streamdevice protocol file for the Siemens SPS-S5 with the custom RS232 interface as used at
# AMOR
InTerminator = "\n";
OutTerminator = "\r\n";
ExtraInput = Ignore;
readDigital {
out "R";
separator="";
in "\?%d";
}
readAnalog {
out "A";
separator="";
in "\?%d";
}
push {
out "%s";
}