# sinqSPS
|
|
|
|
A collection of standardised SPS databases (or "modules") for interacting with
|
|
the control unit itself and other external hardware.
|
|
|
|
This makes use of the
|
|
[s7plcFW Epics driver](https://gitea.psi.ch/lin-epics-modules/sinqS7plcFW) for
|
|
communication with the Siemens 7th Generation PLC via the Fetch-Write Protocol.
|
|
|
|
# Shutter Module
|
|
|
|
This script allows the shutter at the instrument to be opened and closed as
|
|
well as providing access to many status bits and messages.
|
|
|
|
```
|
|
epicsEnvSet("INSTR", "SQ:INSTRUMENT:") # can also be set in runScript call
|
|
|
|
runScript("$(sinqSPS_DIR)shutter.cmd","SPS_IP=172.28.101.26,FETCH_DB=210")
|
|
```
|
|
|
|
The directly exposed database fields can be found in
|
|
[shutter.substitutions](./templates/shutter.substitutions).
|
|
|
|
A simplified status value and status message is created from these fields via
|
|
the logic in [shutter.db](./db/shutter.db).
|
|
|
|
The corresponding nicos device is located at
|
|
[nicos\_sinq/devices/epics/shutter.py](https://gitea.psi.ch/lin-instrument-computers/Nicos/src/branch/release-3.12/nicos_sinq/devices/epics/shutter.py).
|