title: SLS Operation Statistics
description: Weekly and anual operation statistics for the SLS are given here
template: main.html
hide:
- toc
---
<!-- based on old definition Andreas published at http://gfa-operation.intranet.psi.ch/kr/sls/sls_opstat.php
Here are our definitions:
Downtime: time between beam loss (Ibeam < 20mA) and full recovery (Ibeam >= Inominal = 400 mA).
Short-uptime-rule: if two beam outages have less than 1 hour of uptime in between, it is counted as one long downtime.
Scheduled-user-time: this time is distributed between the accepted user proposals
Scheduled-user-reserve-time: additional user time, provided to compensate for beam outages
User-Time: Scheduled-user-time + Scheduled-user-reserve-time
Delivered-beam-time: User-Time - Downtime
Total-downtime: Sum over all individual Downtime of one year
Number-of-faults: Count of all individual Downtimes
Number-of-distortion = Incidence count of Downtimes, beam drops and orbit feedback failures (introduced 2004)
Availability: Delivered-beam-time / User-Time.
Availability after compensation: Delivered-beam-time / Scheduled-user-time.
MTBF: Mean Time Between Failures = User-Time / (Number-of-faults + 1)
MTTR: Mean Time To Recover = Total-downtime / Number-of-faults
MTBD: Mean Time Between Distortions = User Time / Number-of-distortion
-->
??? info "Definitions used for the presented statistics"
* **Scheduled-user-time:** this time is scheduled upfront and distributed between the accepted user proposals
* **Reserve-time:** additional user time, provided to compensate for beam outages (often scheduled mid and end of year, not always used for user operation)
* **User-operation:** Scheduled-user-time + Reserve-time
* **Downtime:** time between beam loss (Ibeam < 20 mA) and full recovery (Ibeam >= Inominal = 400 mA) during user-operation
* **Short-uptime-rule:** if two beam outages have less than 1 hour of uptime in between, it is counted as one long downtime.
* **Total-downtime:** sum of all individual downtimes of one year
* **Total-beam-time** sum of all scheduled beam times (user, beamline, machine, ...)
* **Machine development** sum of scheduled beam times (user, beamline, machine, ...)
* **Delivered-beam-time:** User-operation - Total-downtime
* **Number-of-faults:** incidence count of all individual Downtimes
* **Injector-outage-time:** time between beam drop (Ibeam < 390 mA) and full recovery (Ibeam >= Inominal = 400 mA) during user-operation
* **Number-of-distortions:** incidence count of faults and beam drops, orbit feedback failures, low beam-lifetimes (tau < 8 hours), beam blow ups (sigy > 15 um) and distorted filling patterns
* **Availability:** Delivered-beam-time / User-operation
* **Availability after compensation:** Delivered-beam-time / Scheduled-user-time.
* **MTBF:** Mean Time Between Failures = User-operation / (Number-of-faults + 1)
* **MTTR:** Mean Time To Recover = Total-downtime / Number-of-faults
* **MTBD:** Mean Time Between Distortions = User Time / Number-of-distortion
More information is available in [Phys. Rev. Accel. Beams 19, 082802](https://doi.org/10.1103/PhysRevAccelBeams.19.082802) and [here](http://gfa-operation.intranet.psi.ch/kr/sls/sls_opstat.php).
## 2025
| **DUO Schedule** |||
| :------------------------- | :---------- | :-------- |
| **Time** | **Hours** | **%** |
| Scheduled-user-time | 912 | 10.5 |
| Reserve-time | 48 | 0.5 |
| **User operation** | **960** | **11.0** |
| <!-- --> |
| User operation | 960 | 11.0 |
| Beamline development | 1824 | 20.8 |
| Machine development | 3192 | 36.4 |
| **Total beam time** | **5976** | **68.2** |
| <!-- --> |
| Total beam time | 5976 | 68.2 |
| Shutdown | 2784 | 31.8 |
| **Total** | **8760** | **100.0** |
| **Delivery for total beam time** ||
| :----------------------- | :------- |
| Average beam current | 299 mA |
| Circulating beam dose | 1590 Ah |
| Injected charge | 659.3 μC |
| **Quarterly Beam Dose for Dosimetry** ||
| :------------------------------- | :-------- |
| **Q1** (11.12.2024 - 19.03.2025) | 22.4 Ah |
| **Q2** (19.03.2025 - 18.06.2025) | 450.1 Ah |
| **Q3** (18.06.2025 - 17.09.2025) | 499.7 Ah |
| **Q4** (17.09.2025 - 10.12.2025) | 512.5 Ah |
| **Delivery for User Operation** ||
| :------------------------------ | :--------- |
| User operation | 960 hours |
| Total downtime | 54.1 hours |
| Number-of-faults | 49 |
| Availability | 94.4 % |
| Availability after compensation | 99.3 % |
| MTBF | 19.2 hours |
| MTTR | 1.1 hours |
# DUO Statistics
## 2025
![Pie Chart DUO 2025](data/duostats2025.png){ style="height:400px;" align=left }
| **Time** | **Hours** | **%** |
| :------------------------| :---------- | :-------- |
| {{shutdown}} | 2784 | 31.8 |
| {{machine}} | 3192 | 36.4 |
| {{beamline}} | 1824 | 20.8 |
| {{user}} | 960 | 11.0 |
| **Total** | **8760** | **100.0** |
<div style="clear: both;"></div>
## 2026
![Pie Chart DUO 2026](data/duostats2026.png){ style="height:400px;" align=left }
| **Time** | **Hours** | **%** |
| :------------------------| :---------- | :-------- |
| {{shutdown}} | 4360 | 49.8 |
| {{machine}} | 1632 | 18.6 |
| {{beamline}} | 1032 | 11.8 |
| {{user}} | 1736 | 19.8 |
| **Total** | **8760** | **100.0** |
<div style="clear: both;"></div>
## 2027
![Pie Chart DUO 2027](data/duostats2027.png){ style="height:400px;" align=left }
| **Time** | **Hours** | **%** |
| :------------------------| :---------- | :-------- |
| {{shutdown}} | 2304 | 26.3 |
| {{machine}} | 1904 | 21.7 |
| {{beamline}} | 960 | 11.0 |
| {{user}} | 3592 | 41.0 |
| **Total** | **8760** | **100.0** |
<div style="clear: both;"></div>