@@ -4,15 +4,72 @@ description: Here a list of all uncontrolled / critical beam dumps is kept
template: main.html
---
<!-- Template for entry
## xx - Fri 26-Sep-25 03:37
* BDC Triggered by **xxx** at **xxx mA**
* **Root cause:** xxxx
* **Issue:** xxxx
* more comments
* [https://elog-gfa.psi.ch/SLS/xxxx](https://elog-gfa.psi.ch/SLS/xxxx)
-->
## 14 - Mon 06-Oct-25 18:36
* BDC Triggered by **LLRF for Storage Ring Cavity 3** at **402 mA**
* **Root cause:** Classical ion instability due to bad vacuum in X02SA with U15 gap closed
* **Issue:** Uncontrolled loss of 400 mA at thin septum and collimators
* Filling gap of 50 buckets and vacuum interlock at 1e-7 mbar
* Vacuum interlock is triggered but far too late with 200 ms delay
* [https://elog-gfa.psi.ch/SLS/62668](https://elog-gfa.psi.ch/SLS/62668)
## 13 - Sat 04-Oct-25 17:09
* BDC Triggered by **LLRF for Storage Ring Cavity 2** at **402 mA**
* **Root cause:** xxxx
* **Issue:** Libera data indicates uncontrolled beam loss
* RadFET indicates controlled beam loss
* [https://elog-gfa.psi.ch/SLS/62639](https://elog-gfa.psi.ch/SLS/62639)
## 12 - Tue 30-Sep-25 13:55
* BDC Triggered by **Orbit Deviation** at **53 mA**
* **Root cause:** xxxx
* **Issue:** Uncontrolled beam loss at thin septum
* happened during MD [kw40](https://sls.gitpages.psi.ch/schedule/#2025-kw40)
* [https://elog-gfa.psi.ch/SLS/62568](https://elog-gfa.psi.ch/SLS/62568)
## 11 - Mon 29-Sep-25 17:18
* **Root cause:** Vacuum in injection straight
* **Issue:** Uncontrolled loss of 385 mA at thin septum
* VCS: ARS01 VPIC 0010 :PUMP1-PRESSURE
* Beam lost over ~5 s
* [https://elog-gfa.psi.ch/SLS/62552](https://elog-gfa.psi.ch/SLS/62552)
## 10 - Sun 28-Sep-25 11:10
* **Root cause:** Vacuum in injection straight
* **Issue:** Uncontrolled loss of 400 mA at thin septum
* VCS: ARS01 VPIC 0010 :PUMP1-PRESSURE
* Beam lost over ~5 s
* not clear since RadFET indicates good dump and while Libera loss data does not agree
* steep drop of lifetime before beam loss also indicates uncontrolled beam loss since usually faster than vacuum interlock
* [https://elog-gfa.psi.ch/SLS/62525](https://elog-gfa.psi.ch/SLS/62525)
## 9 - Fri 26-Sep-25 03:37
* **Root cause:** Classical ion instability due to bad vacuum in X02SA with U15 gap closed
* **Issue:** Uncontrolled loss of 400 mA at thin septum and collimators
* Filling gap of 50 buckets and vacuum interlock at 1e-7 mbar
* Vacuum interlock is triggered but far too late with 230 ms delay
* [https://elog-gfa.psi.ch/SLS/62668](https://elog-gfa.psi.ch/SLS/62492)
## 8 - Thu 25-Sep-25 22:58
* **Root cause:** vacuum / ID gap / ion instability
* Repetition of Nr. 7
* Vacuum Interlock threshold now reduced
* Filling pattern gap increased from 30 to 50 buckets
* **Root cause:** Classical ion instability due to bad vacuum in X02SA with U15 gap closed
* **Issue:** Uncontrolled loss of 400 mA at thin septum and collimators
* Filling gap of 30 buckets and vacuum interlock at 4e-7 mbar
* From now on:
* Vacuum Interlock threshold now reduced to 1e-7 mbar
* Filling pattern gap increased from 30 to 50 buckets
* [https://elog-gfa.psi.ch/SLS/62484](https://elog-gfa.psi.ch/SLS/62484)
## 7 - Thu 25-Sep-25 18:04
* **Root cause:** vacuum / ID gap / ion instability
* **Root cause:** Classical ion instability due to bad vacuum in X02SA with U15 gap closed
* **Issue:** Uncontrolled loss of 400 mA at thin septum and collimators
* Beam dump seems to be caused by an initially slow-rising vacuum spike inside the X02SA U15 undulator
* Lifetime went down from 8 hours to <2 hours slowly in the last 5 minutes before the beam dump simultaneously with the pressure going up
* The observed vacuum spike could be a classical ion instability
@@ -22,7 +79,7 @@ template: main.html
* [https://elog-gfa.psi.ch/SLS/62482](https://elog-gfa.psi.ch/SLS/62482)
## 6 - Tue 23-Sep-25 15:56
* Root cause: **FOFB writes bad values to correctors**
* **Root cause:** FOFB writes bad values to correctors
* Happened during BPM Sector reboot, i.e., overall reliability issue with BPM/FOFB system
* Beam dump controller only triggered by RF stations
* Post mortem data clearly shows that beam was lost before dump kicker was fired
+3 -2
View File
@@ -1,5 +1,5 @@
site_name: SLS 2.0 Operations Management
site_description: SLS 2.0 Operations Management
site_name: SLS 2.0 Operation
site_description: SLS 2.0 Operation
site_author: Felix Armborst
# based on CERN PS-MPC site by A. Huschauer
site_url: https://sls.gitpages.psi.ch/
@@ -148,6 +148,7 @@ nav:
- 'Beamlines':
- 'Contacts' : uom/BeamlineContacts.md
- 'UOM minutes': uom/minutes/uom.md
- 'SU Permits' : uom/minutes/uom.md
- 'Schedule' :
- '2025' : schedule.md