define(PLC_Homing='1')
define(statusHoming='P100')
statusHoming=0
//statusHoming:
// 1: M1 phased
// 2: M2 phased
// 4: M1 homed
// 8: M2 homed
// 16: M1 neg limit
// 32: M2 neg limit
// 64: homing done
// 128: homing failed
open plc PLC_Homing
define(timer='L1')
statusHoming=0
L10=Motor[1].MaxDac
Motor[1].MaxDac=500
L11=Motor[1].FatalFeLimit
Motor[1].FatalFeLimit=2000
L12=Motor[1].JogSpeed
Motor[1].JogSpeed=1
L20=Motor[2].MaxDac
Motor[2].MaxDac=500
L21=Motor[2].FatalFeLimit
Motor[2].FatalFeLimit=2000
L22=Motor[2].JogSpeed
Motor[2].JogSpeed=1
Motor[1].PhaseFindingStep=1
Motor[2].PhaseFindingStep=1
timer = Sys.RunTime + 1;while (Sys.RunTime < timer){} //wait 1 sec
Motor[1].HomeVel=2
Motor[2].HomeVel=2
home1
home2
timer = Sys.RunTime + 1;while (Sys.RunTime < timer){} //wait 1 sec
statusHoming|=1
while(1)
{
if(Motor[1].FeFatal && (statusHoming&2)==0)
{
statusHoming=statusHoming|2
Motor[1].HomeVel=-Motor[1].HomeVel
home1
}
if(Motor[2].HomeInProgress==0 && (statusHoming&4)==0)
{
statusHoming=statusHoming|4
Motor[2].HomeVel=-Motor[2].HomeVel
home2
}
if(Motor[1].HomeInProgress==0 && Motor[1].HomeInProgress==0)
{
statusHoming=statusHoming|8
break
}
}
Motor[1].PhasePos=560 // 555 581 593 558
Motor[2].PhasePos=1540 //1549 1531 1543 1537
Motor[1].MaxDac=L10
Motor[1].FatalFeLimit=L11
Motor[1].JogSpeed=L12
Motor[2].MaxDac=L20
Motor[2].FatalFeLimit=L21
Motor[2].JogSpeed=L22
disable plc PLC_Homing
close