Parameters and parameter plots
|
|
==============================
|
|
|
|
The **Parameters** tab shows the numerical model: one row per fitted
|
|
parameter, per data set, with starting values, steps, and limits. Fitting
|
|
feeds the measured values back, and the same table drives the interactive
|
|
parameter plots.
|
|
|
|
.. figure:: images/parameters-tab.png
|
|
:alt: Parameters tab with editable starting values, error or step fields, bounds, and the Plot parameters button.
|
|
:width: 100%
|
|
|
|
Example parameter table before fitting, for the same run and model as
|
|
:doc:`getting-started`. These are initial values, not measured results;
|
|
the Error column contains starting steps at this stage.
|
|
|
|
The parameter table
|
|
-------------------
|
|
|
|
The table is rebuilt automatically whenever the model changes (a new
|
|
component, a new run, a constraint). Rows are keyed to the model:
|
|
|
|
* Single-run fit: one row per parameter of the selected model.
|
|
* Multi-run fit: a row per parameter per data set, each named by its run
|
|
(for example ``Lam_2255``), plus the parameters you choose to share.
|
|
|
|
Rows follow the physical role of each parameter: the initial asymmetry first,
|
|
then the relaxation/lineshape parameters, then the precession frequency, then
|
|
the phase, then the asymmetry alphas and group ratios, and finally the
|
|
detector normalization/background parameters. This ordering is what ends up in
|
|
the generated ``FITPARAMETER`` block and therefore in the ``*_par.dat`` columns
|
|
from ``msr2data``. A parameter introduced through a constraint (for example
|
|
``Bfield = gamma_mu * Frq``) is placed with the built-in parameter it is linked
|
|
to; when it is linked to several parameters it takes the highest-priority
|
|
(lowest) rank among them. An order imported from an existing MSR file always
|
|
overrides this physical sequence.
|
|
|
|
For each parameter the columns are the **starting value**, the **step**, and
|
|
the **lower/upper limits**. Edit any of them directly. Run-scoped parameters
|
|
are matched to their data set by the run suffix, so a per-run starting value
|
|
only affects that run. The values in this table are the starting values used
|
|
for the next fit; after a fit they are replaced by the fitted results, and
|
|
the fit uncertainties are available in the parameter plots as error bars.
|
|
|
|
The **Shared** column
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
In a multi-run fit the table also has a **Shared** column in the first row of
|
|
each parameter. Tick it to keep a single shared starting value, step and
|
|
limits for all runs instead of a separate per-run copy. This is equivalent
|
|
to the musrfit ``GLOBAL`` parameter mechanism.
|
|
|
|
Sharing any parameter takes the fit out of the independent-series route, so
|
|
the per-run refit/skip action chips disappear (see :doc:`runs-fitting`).
|
|
The parameter plot still works.
|
|
|
|
Selecting parameters for plotting
|
|
---------------------------------
|
|
|
|
Click a parameter name to select or deselect it for plotting:
|
|
|
|
* **Click** -- toggle that single parameter.
|
|
* **Ctrl / Cmd-click** -- add an individual parameter without changing the
|
|
rest of the selection.
|
|
* **Shift-click** -- select a contiguous range of parameters.
|
|
* **Long-press (touch)** -- on mobile/tablet, long-press a parameter name to
|
|
add or remove it from the selection without clearing others (multi-select).
|
|
|
|
The selection state is shown in the row. Then use the **Plot parameters...**
|
|
button at the top of the parameter table to open the plot window. If the
|
|
parameter table is not yet populated (no fit run yet and no file loaded), the
|
|
plot can still build the parameter data inline from the table -- the button
|
|
stays enabled whenever the table is built.
|
|
|
|
The Choose X axis dialog
|
|
------------------------
|
|
|
|
The dialog lists the parameter data columns and asks which one to use as the
|
|
common X axis. Each selected parameter becomes a Y series.
|
|
|
|
The dialog also offers the **Layout** of the plot window:
|
|
|
|
* **Auto** -- one parameter per panel. Up to three parameters share a single
|
|
column; beyond that the panels grow toward a square grid (two parameters
|
|
in two columns, three in three, and four or more arranged as the closest
|
|
square grid).
|
|
* **Single row** -- all parameters side by side in one row.
|
|
* **Single column** -- all parameters stacked in one column.
|
|
|
|
The layout choice is remembered for the next plot. The window opens with the
|
|
chosen arrangement, and the **Plot options** panel lets you re-arrange the
|
|
panels afterwards.
|
|
|
|
The parameter-plot window
|
|
-------------------------
|
|
|
|
The window shows one panel per data set / parameter as arranged by the
|
|
layout choice. Panels share the chosen X axis. The toolbar holds:
|
|
|
|
* **Refresh** -- reread the current parameter-data file and redraw every
|
|
visible panel. Use this after a new fit to update the numbers.
|
|
* **Data...** -- change the data set loaded in the *active* panel.
|
|
* **Add data set...** -- choose one or more parameter-data files and overlay
|
|
them onto *every* panel at once. Each file keeps one colour from the
|
|
**Palette**, and every panel plots the parameters it already shows for
|
|
each newly added file, so a scan can be compared against the current one
|
|
across the whole window with a distinct colour. The Y-axis label stays on
|
|
the active panel's parameter rather than reverting to a generic label.
|
|
Adding files this way is the same overlay mechanism as **Overlay data
|
|
sets** in *Plot options*; the toolbar shortcut just applies the additions
|
|
to all panels instead of the active one.
|
|
|
|
Overlaid curves get a *smart legend* label that says which physical state
|
|
each scan represents instead of only a file name. The label is derived from
|
|
the data set's own scan variable and its constant coordinate: an energy scan
|
|
(``dataE`` varying) is tagged with its fixed temperature (``(T = 300 K)``), a
|
|
temperature scan with its fixed energy for LE-µSR (``(E = 12 keV)``) or with
|
|
its field for bulk µSR (``(B = 100 G)``), and a field scan with its fixed
|
|
temperature. When no fixed coordinate is present the plain file label is used.
|
|
You can also rename a legend entry directly in the plot; a Refresh then keeps
|
|
your name instead of rebuilding the default.
|
|
|
|
* **Plot options** -- expand the layout, X, parameter, style, and displayed
|
|
series controls for the active panel.
|
|
|
|
Plot options
|
|
~~~~~~~~~~~~
|
|
|
|
* **Layout** -- the concrete panel grid (for example ``1 x 1`` ... ``3 x 3``
|
|
and larger grids as the panel count needs). Changing it adds or hides
|
|
panels; new panels start empty and clone the sync settings of the current
|
|
panel.
|
|
* **Panel indicator** -- which panel is active (``Panel 1/3``). Click a
|
|
panel to activate it before changing its panel-specific settings.
|
|
* **Data set** -- the data source shown in the active panel.
|
|
* **X** -- the X column for the active panel.
|
|
* **Parameter** -- add a Y parameter to the active panel. Serial chips
|
|
underneath list the current Y series; click the ``x`` on a chip to remove
|
|
that series.
|
|
* **Style** -- ``Scatter``, ``Lines + markers``, or ``Lines``.
|
|
* **Palette** -- the base colour palette (``Default``, ``Bold``,
|
|
``Pastel``, ``Monochrome``) used to assign each overlaid data set its
|
|
default colour. Changing it restyles every panel.
|
|
* **X title / Y title** -- override the automatic axis label of the active
|
|
panel; leave empty to keep the automatic label.
|
|
|
|
.. _Remembered plot configurations:
|
|
|
|
Remembered plot configurations
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The full window state is remembered per data source: the panel arrangement,
|
|
the X column, the template, the palette, the per-series styles (including the
|
|
error-bar caps setting), and the overlay files. A configuration is keyed by the
|
|
data source *and* the parameter set it plots, so each parameter selection has
|
|
its own remembered configuration.
|
|
|
|
Restoring a configuration is always an explicit choice, never something that
|
|
happens behind your back:
|
|
|
|
* The **Choose X axis** dialog appears every time you plot parameters.
|
|
* If a remembered configuration matches the parameters you selected (the same
|
|
set, in any order), a **Configuration** dropdown appears in the dialog. The
|
|
most recent matching configuration is preselected; the dialog shows exactly
|
|
what will be restored, and you press **Plot** to confirm.
|
|
* Choosing **From scratch** in the dropdown (or having no matching
|
|
configuration) starts a normal new window from the X axis and layout choices
|
|
on the dialog.
|
|
|
|
Matching is exact: a saved configuration for three parameters never shows up
|
|
for a one-parameter request, even if that one parameter is part of the three.
|
|
|
|
* State is keyed by the data source, so ``scanA_par.dat`` keeps its own styles
|
|
and layout while other files (and their overlay sets) remember theirs
|
|
independently.
|
|
* Up to eight data sources are remembered; adding a new one forgets the
|
|
oldest. Each source keeps at most one configuration per parameter set (the
|
|
newest wins) and a handful of parameter sets in total.
|
|
* **Forget plot configuration** in **Plot options** clears the remembered state
|
|
for the data source shown in the active panel, so the **Choose X axis**
|
|
dialog offers no configuration next time.
|
|
* The remembered configuration of the current data source is carried in
|
|
configuration share links, so a colleague restoring your link gets the same
|
|
plot window -- see :doc:`configuration-sharing`. When a real fit produced the
|
|
parameter table, the table itself is embedded in the link (inline text) and a
|
|
web restoration renders the identical plot immediately, without needing a
|
|
local or server-side fit.
|
|
* Uploaded files keep only their identity, not their contents: if the original
|
|
file cannot be read again (for example it was deleted), the restored plot
|
|
degrades gracefully and the dialog is offered instead.
|
|
|
|
Overlay data sets (multiple files in one panel)
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Panels can plot several ``*.dat`` files at once so scans can be compared on
|
|
one set of axes. Open **Plot options** and use **Overlay data sets > Add
|
|
file...** to choose extra parameter-data files (on the desktop this is a
|
|
native multi-select dialog; on the web it is the browser's multi-file
|
|
picker). Each file becomes a row with a checkbox:
|
|
|
|
* checked rows are drawn on top of the panel's main data set;
|
|
* the colour swatch shows the default trace colour for that file, assigned
|
|
from the **Palette**;
|
|
* files are identified by their resolved path or blob identity, so picking
|
|
the same file twice keeps one entry -- and one user-adjusted style;
|
|
* the X axis is aligned across files **by column name** -- a file that does
|
|
not contain the panel's X column is skipped and named in a striped note
|
|
under the panel;
|
|
* in overlay mode each file's traces share its colour, and legend entries
|
|
are prefixed with the file name (``scanB_par.dat: λ₁``).
|
|
|
|
Growing the layout clones the active panel, so expanding a ``1 x 1`` grid to
|
|
``2 x 1`` carries the overlay files into the new panel. Unchecking a row
|
|
removes that file from the active panel only; the file stays available in the
|
|
list for other panels.
|
|
|
|
Worked example: energy scan at two temperatures
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
See :doc:`lem2025-singlehist-example` for the complete illustrated walkthrough
|
|
and reproducible results. It uses **new single-histogram fits** of LEM 2025
|
|
runs 1014-1027 (blue, 3.8 K) and 1033-1045 (red, 10 K), not the older
|
|
asymmetry-fit reference tables.
|
|
|
|
.. figure:: images/lem2025-singlehist-comparison.png
|
|
:alt: Actual muSRFlow comparison of field, sigma and initial asymmetry versus energy, with blue and red data sets and fit error bars.
|
|
:width: 75%
|
|
|
|
Three vertically stacked panels from the application, using the newly
|
|
fitted single-histogram tables. Both data sets are overlaid in each panel.
|
|
The example chapter explains the model, histogram grouping, uncertainties
|
|
and limitations; results are in
|
|
``docs/examples/lem2025-singlehist-energy-scan``.
|
|
|
|
Editing trace styles
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Click any marker directly in a plot panel to open a small style editor near
|
|
the pointer:
|
|
|
|
* **This trace / This data set** -- whether the change applies to the clicked
|
|
(file, parameter) series only, or to every trace of that data set (all
|
|
panels showing it). Choosing **This data set** unifies the whole file and
|
|
clears any per-panel trace styling left behind, so those panels no longer
|
|
shadow the new style.
|
|
* colour swatches, marker **symbol**, **size**, and **opacity**;
|
|
* **Error-bar caps** -- error bars are plain vertical lines unless the
|
|
checkbox is ticked, which draws the cross-bars at both ends;
|
|
* **Apply** -- commit the staged choices and redraw the affected panels;
|
|
**Close** hides the editor, and ESC (or ``Q``) dismisses it;
|
|
* **Reset** -- restore the file's default colouring for that scope.
|
|
|
|
Trace-level edits are keyed by (data set, panel, parameter), so they survive
|
|
panel re-layouts but never leak onto other panels. Data-set-level edits are
|
|
shared: recolour ``scanA_par.dat`` once, and every panel that shows it
|
|
updates. ``Esc`` (or ``Q``) closes the editor; the title bar is a drag
|
|
handle so the panel can be repositioned within the parameter-plot window.
|
|
|
|
Template and series presets
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The **Template** dropdown applies a predefined multi-panel arrangement that
|
|
maps recognised parameter names to roles. For example the ``tf-scan``
|
|
template lays out three panels -- amplitude, damping, and frequency -- above
|
|
one another. Parameters that cannot be matched to the data are omitted
|
|
rather than guessed; unmatched panels stay empty.
|
|
|
|
Keyboard shortcuts
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
With a panel focused (and not while typing in a field), the shortcut keys are:
|
|
|
|
* ``u`` -- reset the active panel to its automatic X and Y ranges.
|
|
* ``Q`` or ``Esc`` -- close the plot window.
|
|
|
|
The plotly mode bar at the top-right of each panel provides zoom, pan, box
|
|
select, and download, and a custom button toggles each axis between linear
|
|
and logarithmic. Trace colours are assigned automatically per series --
|
|
clicking a marker opens the style editor described above to change them.
|