Click a plotted marker to open a style editor (colour, symbol, size, opacity) scoped to the trace or the whole data set, driven by a shared per-window style registry. Panels can overlay several *.dat files from any platform: Plot options > Overlay data sets stores a window-level dataset registry, aligns files by column name, skips missing X columns with a per-panel note, and draws each file in a palette-assigned colour. A palette selector and per-panel axis-title overrides round out the Plot options panel. Electron gets a selectParameterDataFiles IPC channel for the native multi-select dialog; the web uses the browser multi-file picker. Documents the new controls and adds style/overlay/registry tests to the parameter-plot suite.
87 lines
3.6 KiB
ReStructuredText
87 lines
3.6 KiB
ReStructuredText
Troubleshooting
|
|
===============
|
|
|
|
Fit or plot will not start
|
|
--------------------------
|
|
|
|
Check the resolution warning under the run row: it reports runs that cannot
|
|
be resolved against the current data tree. In the browser edition, confirm
|
|
the server exposes those runs; on the desktop, verify the data directory
|
|
preference points at the real data root. If a model has no valid run, the
|
|
action reports the reason in the outcome dialog and the run log.
|
|
|
|
"Nothing to fit"
|
|
----------------
|
|
|
|
An independent-series fit (two or more data sets, no shared parameters) where
|
|
every run is set to **skip** reports this instead of running. Set at least
|
|
one chip to **reuse** or **refit**, or use **Refit all** from the All
|
|
dropdown.
|
|
|
|
Fitted parameters look wrong or unchanged
|
|
-----------------------------------------
|
|
|
|
* The parameter table is the source of the *starting* values. After a fit it
|
|
holds the fitted results; run the fit again after editing values.
|
|
* Hand-edited MSR documents are authoritative: if the editor lock is closed,
|
|
Fit and Plot use the editor text and ignore GUI changes until you unlock
|
|
(see :doc:`msr-editor`).
|
|
* A model change rebuilds the parameter table and may reset values; re-check
|
|
the rows for every component you use.
|
|
|
|
Parameter plot is empty or missing data
|
|
---------------------------------------
|
|
|
|
* Click **Refresh** after a new fit -- panels reread the parameter file.
|
|
* Use **Data...** to change the data set of the active panel.
|
|
* A panel that shares the X axis with no plottable column shows its empty
|
|
message; activate it and add a parameter or load another file.
|
|
* Overlaid files that lack the panel's X column (or could not be re-read)
|
|
are skipped and listed in a striped note under the panel. Fix the X
|
|
column (**X** control) or uncheck the file under **Plot options > Overlay
|
|
data sets**.
|
|
|
|
Parameter plot hangs on "Preparing plot files"
|
|
----------------------------------------------
|
|
|
|
"Preparing plot files" covers the setup performed before the tools run. If
|
|
the step never finishes, check the server/work-bench side:
|
|
|
|
* The command-line tools must be reachable on the machine that runs them
|
|
(local install on the desktop, server-side install for the CGI).
|
|
* On the desktop, confirm the work directory is writable.
|
|
|
|
The command log records every command line that was attempted; it is the
|
|
first place to look.
|
|
|
|
Web page cannot load data
|
|
-------------------------
|
|
|
|
The browser edition fetches data and runs fits on the server. If the page
|
|
loads but actions fail, verify the CGI endpoint is reachable (see
|
|
``cgi/README.md``) and that the server data root matches what the page was
|
|
deployed with. The server health endpoint reports the configured data root;
|
|
muSRFlow's resolution warning should agree with it.
|
|
|
|
Restored configuration differs from the original machine
|
|
--------------------------------------------------------
|
|
|
|
Configuration links carry analysis settings only, not data or working
|
|
directories. On a different machine the same settings resolve against that
|
|
machine's data tree. If runs do not resolve, fix the data/startup-XML
|
|
configuration (desktop Preferences; server configuration on the web) and
|
|
refit.
|
|
|
|
Some links start with a different prefix
|
|
----------------------------------------
|
|
|
|
muSRFlow shares both a compact compressed form (``#c=``) and a readable
|
|
legacy form (``#cfg=``). Both are accepted by the web and the desktop
|
|
restore dialog.
|
|
|
|
Reporting problems
|
|
------------------
|
|
|
|
Include the command log (open from the status bar or the outcome dialog)
|
|
and the versions involved. Contact Zaher Salman
|
|
`<zaher.salman@psi.ch>`_ with those details for the fastest help. |