Example Parameters
ROUNDS = 1
E1 = 634
E2 = 665
TIME = 2
DELAY = 3
PLOT_TYPE = 1
OFFSET1 = -2.0 #eV
OFFSET2 = -2.9 #eV
RUNTYPE = "+/-"
"""
print "\nStarting energy scan - Parameters: ",
print E1,E2,TIME,ROUNDS,RUNTYPE
run("utils")
polswitch = 1
##################### Setting filenames #######################################
file_prefix = time.strftime("%Y%m%d")
fid = get_next_fid(input_path, "o" + file_prefix)
sep = "\t"
line_sep = "\r\n"
# CHANGE THE PATH IN THE OTF
input_path = PATH
output_path = input_path
###############################################################################
#Prepare scan
###############################################################################
caput ("X11PHS-E:OPT","PGM+ID1+ID2")
if RUNTYPE in ["+/-", "+", "-"]:
caput(ID1_MODE,1) # circ + in ID1
caput(ID2_MODE,2) # circ - in ID2
wait_channel(ALL_DONE, 1, type = 'i')
if RUNTYPE == "+/-":
number_of_scans = 2 * ROUNDS
else:
number_of_scans = ROUNDS
elif RUNTYPE in ["LH/LV", "LH", "LV"]:
caput(ID1_MODE,0)
caput(ID2_MODE,0)
wait_channel(ALL_DONE, 1, type = 'i')
caput(ID1_ALPHA, 0.0) # LH in ID1
caput(ID2_ALPHA, 90.0) # LV in ID2
wait_channel(ALL_DONE, 1, type = 'i')
if RUNTYPE == "LH/LV":
number_of_scans = 2 * ROUNDS
else:
number_of_scans = ROUNDS
else:
raise Exception("Invalid run type: " + RUNTYPE)
if RUNTYPE in ["-", "LV"]:
switchpol(2, RUNTYPE) # tune ID2 --> polarization: C- or LV
polswitch = 0
elif RUNTYPE in ["+/-", "+", "LH/LV", "LH"]:
switchpol(1, RUNTYPE) # tune ID1 --> polarization: C+ or LH
time.sleep(1.0)
wait_channel(ALL_DONE, 1, type = 'i')
open_vg10()
time.sleep(0.5)
open_vg11()
time.sleep(0.5)
open_vg12()
time.sleep(0.5)
open_vg13()
###############################################################################
#Main scan loop
###############################################################################
for scan_no in range(number_of_scans):
suffix = ("%03d" % fid)
input_file = input_path + "o" + file_prefix + "_" + suffix + ".dat"
caput(OTF_E1, E1)
caput(OTF_E2, E2)
caput(OTF_TIME, TIME)
caput(OTF_FTS,file_prefix)
caput(OTF_FID,fid)
caput(ENERGY_SP, E1)
wait_channel(ALL_DONE, 1, type = 'i')
time.sleep(DELAY)
startPlot(PLOT_TYPE)
otf_start.write(1)
time.sleep(1.0)
print "Running scan " + str(scan_no+1) + " out of " + str(number_of_scans)
try:
otf_start.waitValue(0, (15 + int(TIME*60)) *1000)
except:
print "******** OTF STOP TIMEOUT **********"
otf_start.write(0)
finally:
stopPlot()
time.sleep(1.0)
#Convert file
output_file = output_path + "os" + file_prefix + "_" + suffix + ".dat"
print("Converting data file: " + output_file);
convert_file(input_file, output_file)
plot_file(output_file, file_prefix+"_" + suffix) #"comment to supress plot
print "Finished scan " + str(scan_no+1) + " out of " + str(number_of_scans) + " with polarisation: " + get_pol_str()
if RUNTYPE in ["+/-", "LH/LV"]:
if polswitch == 1:
switchpol(2, RUNTYPE) # tune ID2 --> polarization: C- or LV
polswitch = 0
else:
polswitch = 1
switchpol(1, RUNTYPE) # tune ID1 --> polarization: C+ or LH
else:
print "running in one polarization mode, no switching"
time.sleep(3.0)
fid = fid + 1
###############################################################################
#Finishing scan
###############################################################################
caput(ENERGY_SP, E1)
close_vg13()
print "Successfully Finished Energy scan"