Script execution
This commit is contained in:
@@ -1,9 +1,10 @@
|
||||
#Script imported from: Fe_hyst_plus.xml
|
||||
|
||||
#Parameters
|
||||
START_FIELD = -1.0
|
||||
END_FIELD = 1.0
|
||||
START_FIELD = 1.0
|
||||
END_FIELD = -1.0
|
||||
ENERGIES = (707.90, 703.90)
|
||||
RAMP_RATE = 2.0
|
||||
|
||||
#Pre-actions
|
||||
#cawait('ACOAU-ACCU:OP-MODE', 'Light Available', type = 's')
|
||||
@@ -13,18 +14,18 @@ sleep(1.0)
|
||||
#caput('X07MA-ID:ENERGY-OFFS', '-1.0')
|
||||
#cawait('X07MA-ID:DONE', 'DONE', type = 's')
|
||||
caputq('X07MA-PC:CSCALER.INPB', '1')
|
||||
caputq('X07MA-PC-PS2:SET:DMD:RAMPRATE:TPM', '2.0')
|
||||
caputq('X07MA-PC-PS2:SET:DMD:RAMPRATE:TPM', RAMP_RATE)
|
||||
#sleep(15.0)
|
||||
|
||||
set_preference(Preference.ENABLED_PLOTS, ['FieldRbk', 'tey_norm', 'trans_norm'])
|
||||
set_preference(Preference.PLOT_TYPES, {'FieldRbk':1, 'tey_norm':1, 'trans_norm':1})
|
||||
set_preference(Preference.ENABLED_PLOTS, ['tey_norm', 'trans_norm'])
|
||||
set_preference(Preference.PLOT_TYPES, {'tey_norm':1, 'trans_norm':1})
|
||||
|
||||
#TODO:
|
||||
#Option to have time scane for X
|
||||
#Separate 2 series in 1D plot
|
||||
#Plot differences of 2 plotsin tey_norm
|
||||
|
||||
scan = ManualScan(['index', 'Energy'], ['FieldRbk', 'TEY', 'I0', 'trans', 'polarization', 'polAngle', 'temperature', 'RingCurrent', 'fieldAnalogX', 'tey_norm', 'trans_norm'])
|
||||
scan = ManualScan(['field', 'Energy'], ['TEY', 'I0', 'trans', 'polarization', 'polAngle', 'temperature', 'RingCurrent', 'fieldAnalogX', 'tey_norm', 'trans_norm'])
|
||||
scan.start()
|
||||
|
||||
#Stop condition
|
||||
@@ -58,7 +59,12 @@ fieldAnalogX = Channel('X07MA-ES1-AI:SIGNAL4', type = 'd')
|
||||
#Dimension 1
|
||||
#RegionPositioner field
|
||||
#Region 1 pre-actions
|
||||
|
||||
print "Waiting for start field"
|
||||
#WORKAROUND TO BUG IN DRIVER
|
||||
if abs(fieldReadback.get() - START_FIELD) < 0.005:
|
||||
caput('X07MA-PC-PS2:M:GO.A', START_FIELD + 0.01)
|
||||
|
||||
caput('X07MA-PC-PS2:M:GO.A', START_FIELD)
|
||||
print "Set end field"
|
||||
caputq('X07MA-PC-PS2:M:GO.A', END_FIELD)
|
||||
@@ -109,7 +115,7 @@ while(True):
|
||||
#TODO: Move, if needed, this import to the file header: import math
|
||||
trans_norm = detector3/detector2
|
||||
|
||||
scan.append ([index, setpoint2], [index, readback2], [field_readback, detector1, detector2, detector3, detector4, detector5, detector6, detector7, detector8, tey_norm, trans_norm])
|
||||
scan.append ([field_readback, setpoint2], [field_readback, readback2], [detector1, detector2, detector3, detector4, detector5, detector6, detector7, detector8, tey_norm, trans_norm])
|
||||
|
||||
|
||||
print "Field = " + str(fieldReadback.get())
|
||||
|
||||
Reference in New Issue