c40e09d458f46b0846c4cc39da705f44294f2b73
The two-arm check for "same order, different symmetry" ran after the all-observation arm had already been adopted by value, so it compared that arm against a copy of itself: the point-group names were always equal and the branch was dead. In the other direction the orders were always unequal, so it was dead there too. The AMBIGUOUS warning - written for the case where the two merges support different symmetries of the same order, which implies two different molecular-replacement searches - could never be emitted. Check before the adoption, while both arms still hold their own result. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>