8fa5b14bc03f97fa61f7d47b5cc7315cd412445f
Each refit reads a share of the error left, so the walk's steps contract by about the ratio of the
last two. Where the step that ratio predicts moves the end of the sweep by less than half a frame,
the refit (an integration of the pre-pass frames and a post-refinement) and the indexing probe after
it are not made; the scale the validation frames last preferred is adopted, as before.
Measured on the walk sets of the battery against rc175 edde4439c: p.hkl and MTZ data identical; it
fired on one open set (2 refits instead of 3, same adopted scale), about -7 s there.
Co-Authored-By: Claude Opus 5.5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01EizBKhTqrAYago9KJG3dA3
Jungfraujoch
Application to receive and analyse data from the PSI JUNGFRAU and EIGER detectors, together with
rugnux, its program for processing stored diffraction data - rotation and serial, macromolecular
and small-molecule - from images to merged reflections.