The gain of an input in detector units (SMV, marCCD, XTC, the XFEL formats) is measured once, before anything reads the frames (RugnuxMeasureGain: photon-peak spacing and background variance per unit mean), or given with --gain, and handed to the integration and the spot finding by one function (ApplyRugnuxPixelGain). The rotation pre-scan no longer measures it, and the stills reader no longer converts frames of a detector whose photons are not resolved: SACLA MPCCD, Rayonix and CCD frames are integrated in ADU at the gain, rotation and stills alike. Where a photon count was assumed, it is now taken at the gain (bit-identical at gain 1): - integration: the background clip's one-photon floor, the sigma floor (one photon), the profile fit's background floor (0.01 photon), and a still's overload kept as a lower bound, which was left in ADU while every other reflection left the integrator in photons - the cause of the earlier loss of the engine route on clipped CCD stills (merged low resolution inflated by the gain, the rocking-width fit's bandwidth collapsing); CPU and CUDA, Metal through the shared CPU code; - the adaptive spot threshold (Poisson arm and its one-photon floor), CPU and GPU; - the pre-scan spot-width measurement (strong-spot SNR, the ring clip) behind the stills bandwidth and the rotation signal radius; - the hot/dead pixel tests, CPU and GPU; the empty-aperture ring clip. BackgroundPixelGain is gone: one pixel_gain. A detector whose background resolves single photons (photon peaks: JUNGFRAU in keV, AGIPD) is a photon counter and its frames are still counted in whole photons as read: analysed in keV at the gain instead, a photon-counting still set lost 0.008 R-free (fewer spots, a noisier beam-centre trial) - the rounding is the detector's own discrimination. --gain sets the value, the background still says which kind. Validation, against rc178: photon-counting and g<=1 rotation p.hkl md5-identical (lyso, thau, cytc, myob, insu, a small-molecule set, 5reo, 6cee, 6i3j, 2xfw, 6s1u, 8v4j); CCD g>1 at or within noise of rc178 (5uth R_meas 0.113 -> 0.108). Stills R-free (0-cycle REFMAC): MPCCD sets 0.184 -> 0.185 and 0.199 -> 0.196, Rayonix identical, photon-resolving sets back on their rc178 numbers. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_015CeEGgpKdfkCTJb3YNMJcu (cherry picked from commit da8dbfc8147354b63e375f2d9521dffb80938b6d)
Jungfraujoch
Application to receive and analyse data from the PSI JUNGFRAU and EIGER detectors, together with
rugnux, its program for processing stored diffraction data - rotation and serial, macromolecular
and small-molecule - from images to merged reflections.
All documentation is now placed in docs/ subdirectory and for the current version hosted on Jungfraujoch Read The Docs page.
Description
Jungfraujoch Data Acquisition System, Rugnux Data Processing Application, and Diffraction Viewer
3 GiB
2 Stars
3 Watchers
0 Forks
Languages
C++
77.8%
HTML
5.3%
Cuda
4.5%
C
3.8%
TypeScript
3.5%
Other
5%