The expected-variance weights decompose an observation's sigma^2 into a background part and a Poisson signal part, then rebuild the signal part at the reflection's merged mean. The decomposition subtracted corr*I with I taken as-is, so a negative I ADDED to the background part: an observation at I = -1.5 with sigma^2 = 1 came out with a base variance of 2.7 rather than 1. That inflates the variance of precisely the down-fluctuated observations the correction exists for. Below about one photon they are then under-weighted and the merged mean is biased high - the same direction of error, in the same regime, that weighting by the observation's own sigma produces. Subtract max(0, I) instead: a negative intensity has no Poisson signal to remove. Both users of the decomposition are fixed - the stills merge, where expected-variance weighting is now the default, and the rotation combine it was mirrored from, which had it first. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>