Files
Jungfraujoch/docs/TESTS.md
T
leonarski_fandClaude Opus 5.5 9537bc9d01 docs: Measuring Rugnux - the battery, the REFMAC check, the timing benchmark, and how to take timings
One page (docs/RUGNUX_BENCHMARKING.md, in the rugnux toctree) for anyone measuring rugnux on another
machine: the battery protocol (arms, one command per arm, verdicts, the --report-resolution
like-for-like table, run directory, compare, the rules), exactly what model_check.py runs (first
REFMAC rigid-body cycle of the deposited model at the common d_min, the depositor's data as
baseline, the refined shared-free-set protocol) and its limits, the three-set timing benchmark and
its checks, the practical lessons on timing (CI flags, first run after a build, quiet machine,
ABAB, page cache, GPU lock, Windows WDDM paging, macOS unified memory, memory peaks, TIMING lines,
NVTX), and the layout of a pack to send back. Linked from RUGNUX.md, TESTS.md (whose battery
description still spoke of variants) and tools/battery/README.md, which also notes the two
site-config snags met on Windows and macOS (relative paths, a copied pdb_cache).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01PXc1zD1yxHqaR1DGdCTHL4
2026-10-16 08:16:55 +02:00

7.6 KiB

Tests

The unit and integration tests are written with Catch2 and collected into a single binary, tests/jfjoch_test. Build and run it with:

make -j$(nproc) jfjoch_test
cd tests
./jfjoch_test                 # everything
./jfjoch_test "<test name>"   # one test case
./jfjoch_test "[tag]"         # by tag

There are also benchmark and hardware routines, each printing its own usage:

  • jfjoch_hdf5_test to measure HDF5 dataset writing speed (single threaded). It doubles as the generator of the HDF5 files used by the external-software tests below.
  • jfjoch_lite_perf_test to measure the CPU/GPU ("lite") analysis path - indexing, integration and optional file writing.
  • jfjoch_fpga_test to test quality/performance of FPGA card(s) and software routines. With -H it runs the high-level-synthesis C model on the CPU, so no FPGA device is needed.

Out-of-space handling is covered separately by jfjoch_hdf5_enospc_test, run under the enospc_shim LD_PRELOAD module that makes writes fail with ENOSPC.

In addition, tests are executed to verify that datasets written by Jungfraujoch are readable by other MX software (see Integration with MX data processing software) - XDS through the Jungfraujoch, Durin and Neggia plugins, and DIALS xia2.ssx - for each of the NXmx layouts. Input files for these programs are placed in the tests/xds, tests/xds_durin, tests/xds_neggia and tests/crystfel folders. See .gitea/workflows/build_and_test.yml for the exact commands; the CrystFEL fixtures are run by hand rather than in the pipeline.

Judging a change to the analysis itself

The harnesses below run rugnux over stored datasets and score the result. None is part of CI - run them when a change plausibly moves merged results, not as a reflex. The public datasets the pipeline is exercised on, and the DOI to cite for each, are listed in External test data.

  • tools/battery/battery.py - the rotation battery, the one canonical way to judge a rotation change: public PDB depositions scored against the deposition, in-house standard crystals and no-crystal controls scored against XDS, and a local-only private arm. Its manifests, the run and compare protocol and the report are described in tools/battery/README.md. Each set runs once, with one command per arm; Measuring Rugnux explains the protocol, the REFMAC check and the timing benchmark, and how to take timings that compare.
  • rugnux_stills_ab.py - the stills analogue of the battery: scores a change on a serial dataset by what it does to the merge. Takes its dataset list from outside the repository.
  • rugnux_anomalous.py - the anomalous-peak-height arbiter, below.

The anomalous-peak-height arbiter

A change that touches partiality - a mosaicity estimator, a rocking-curve model, a background change, anything that alters how partial reflections are weighted - cannot be judged by the statistics we normally reach for:

statistic why it fails for this class of change
ISa, R_meas, error-model b one measurement, not three; dominated by the low-resolution shells; not invariant to the uniform intensity rescale a partiality change produces
last-shell R_meas moves with its denominator, i.e. the wrong way by construction
rugnux --model R-free tracks its own zero-information floor, which moves ~22x more than R-free itself over the same sweep
per-shell agreement with XDS_ASCII.HKL XDS never divides by partiality, so "divide less" moves us toward it mechanically; measured to put the optimum ~1.4x too low

Anomalous difference density at known scatterer sites has none of these problems. It is read in units of the map's own sigma, so a uniform intensity rescale cancels exactly, and it is referenced to the structure rather than to another program's partiality model.

rugnux_anomalous.py measures it: shelxc + anode -a (CCP4) on each arm's merged reflections, against a model that is placed once and then held fixed. It reports, per dataset, the mean site height and the off-site noise floor, and, between arms, the paired per-site change.

# compare two arms (each a directory of <id>/<id>.hkl + .mtz)
./rugnux_anomalous.py --config <table>.json  base=<dir-A>  test=<dir-B>

# a parameter scan: numeric labels turn the arms into a curve with a per-dataset optimum
./rugnux_anomalous.py --config <table>.json \
    0.85='<scan>/{name}/s0p85.hkl' 1.00='<scan>/{name}/s1.hkl' 1.20='<scan>/{name}/s1p2.hkl'

An arm is a Rugnux output directory or a path template containing {name}. --place does the one-off model placement, --write-config-template prints the config skeleton, and ANODE results are cached under the config's workdir (a full 9-dataset x 11-arm scan takes under a minute).

The gate. A dataset counts only if its reference arm shows top peak > 1.5x the highest off-site peak and at least 3 sites over 5 sigma. A dataset that fails is reported as EXCLUDED, never as a zero - the difference between two noise measurements is not a measurement.

Standing dataset set (2026-08): 8 datasets from 7 crystals - 114 site-measurements across the datasets, 108 distinct sulfur sites - all judged on native sulfur signal.

crystals space group photon energy sites each
2 P41212 12.4, 16.0 keV 18
2 (lysozyme) P43212 13.0, 5.0 keV 27
3 (4 datasets - one crystal contributes two energies) cubic, I-centred 13.0, 6.0, 5.0, 5.0 keV 6

Report n as crystals, not datasets: two energies of one crystal are not two independent votes, and the tool prints both counts for that reason.

Traps this tool exists to encapsulate. Every one of them has already cost a working day:

  1. The phasing space group comes from the config, never from the merged file. I23 and I213 have identical systematic absences (I-centring already forces the screw condition), so no data can separate them, and phaser's automatic space-group test only tries the enantiomorph - which for I23 is itself. Phasing an I-centred cubic case in the I23 that both Rugnux and XDS report gives TFZ 7-11 where the other member gives 30-50, and drops the mean site height by a factor 3-10 - enough to make four good datasets look signal-free. Thirteen classes of chiral space group are indistinguishable this way; --place tries every member of the class and reports each one's LLG/TFZ.
  2. Place the model once, from a reference arm, and reuse it unchanged. Re-phasing per arm lets the model move and contaminates the comparison. Refining the placed model against the dataset's own amplitudes is allowed (it lifts the peaks another 4-10%) as long as the same refined model is then used for every arm.
  3. The gate and the measurement must use the same model. Gating on one model and scoring the curve with another silently changes which datasets are in the set.
  4. The off-site floor skips special positions. A peak on the cell origin is a ripple of the calculated phases, not a sample of the background; leaving it in inflates the floor by several sigma and can turn a passing dataset into a failing one. Such peaks are reported in their own spec column rather than dropped silently.

Reading the result. Judge the paired per-site change, with its standard error, pooled over crystals. A per-dataset optimum whose arm does not beat the reference on the paired test is flagged not significant vs ref and must not be quoted as a preference; so must one sitting on the edge of the scanned grid (grid edge) - extend the grid instead.