leonarski_fandClaude Opus 5 42eb5bbe83 rugnux: clamp the refinement thread count to what the setting accepts
RefineThreads rejects anything above 64, and the two-pass rotation path - the default -
passed nthreads/2 straight from the machine. On a host with 130 or more hardware
threads rugnux therefore exited 1 with the bare message "Candidate-cell refinement
thread count" before reading a single image, and the only workaround was to discover -N
and pass a smaller value. Dual 64-core parts are squarely in range.

The limit is now a named constant the setter and the callers share, so the two cannot
drift apart again.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-03 14:14:09 +02:00
2026-07-11 07:19:11 +02:00
2026-07-19 09:39:28 +02:00
2025-12-04 11:56:14 +01:00
2026-07-13 13:54:03 +02:00
2026-07-12 19:42:29 +02:00
2026-03-26 20:50:33 +01:00
2026-06-23 20:29:49 +02:00
2026-06-23 20:29:49 +02:00
2026-07-19 09:39:28 +02:00
2026-07-12 19:42:29 +02:00
2026-07-19 09:39:28 +02:00
2026-06-13 21:27:41 +02:00
2026-06-23 20:29:49 +02:00
2024-11-22 21:25:20 +01:00
2026-07-12 19:42:29 +02:00
2024-12-02 21:17:14 +01:00
2026-02-18 16:17:21 +01:00
2025-10-25 22:05:47 +02:00
2026-07-03 19:18:56 +02:00
2026-06-23 20:29:49 +02:00
2026-06-23 20:29:49 +02:00
2024-12-02 21:17:14 +01:00
2026-07-19 09:39:28 +02:00
2026-06-23 20:29:49 +02:00
2026-07-28 21:58:00 +02:00

Jungfraujoch

Application to receive data from the PSI JUNGFRAU and EIGER detectors.

All documentation is now placed in docs/ subdirectory and for the current version hosted on Jungfraujoch Read The Docs page.

S
Description
Jungfraujoch Data Acquisition System
Readme GPL-3.0
3 GiB
Languages
C++ 73.7%
HTML 8.8%
C 7%
TypeScript 4.8%
Tcl 2.5%
Other 3.1%