leonarski_fandClaude Opus 5 3d4209d803 docs: the first-pass ice measurement, the promotion fix, and powder-ring geometry
Changelog entries for the three changes above, and a new CPU_DATA_ANALYSIS
section on determining detector geometry from powder rings: why a ring is an
independent constraint on the beam centre (it has no crystal orientation to be
gauge-coupled to, unlike everything else that fits geometry here), what a ring
can and cannot determine, and how the ring points are obtained.

The section states the harmonics correctly, which is worth writing down because
the intuitive version is wrong: a detector tilt shows up as cos(phi), the same
harmonic as a beam-centre error, and the two are separated by the amplitude
growing as the ring radius SQUARED - so it takes at least two rings, and on one
ring they are exactly degenerate. The genuine cos(2 phi) term is hundredths of a
pixel.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-06 22:12:21 +02:00
2026-07-11 07:19:11 +02:00
2026-07-19 09:39:28 +02:00
2025-12-04 11:56:14 +01:00
2026-07-13 13:54:03 +02:00
2026-07-12 19:42:29 +02:00
2026-03-26 20:50:33 +01:00
2026-06-23 20:29:49 +02:00
2026-06-23 20:29:49 +02:00
2026-07-19 09:39:28 +02:00
2026-07-12 19:42:29 +02:00
2026-07-19 09:39:28 +02:00
2026-06-13 21:27:41 +02:00
2026-06-23 20:29:49 +02:00
2024-11-22 21:25:20 +01:00
2024-12-02 21:17:14 +01:00
2025-10-25 22:05:47 +02:00
2026-07-03 19:18:56 +02:00
2026-06-23 20:29:49 +02:00
2024-12-02 21:17:14 +01:00
2026-06-23 20:29:49 +02:00
2026-07-28 21:58:00 +02:00

Jungfraujoch

Application to receive data from the PSI JUNGFRAU and EIGER detectors.

All documentation is now placed in docs/ subdirectory and for the current version hosted on Jungfraujoch Read The Docs page.

S
Description
Jungfraujoch Data Acquisition System
Readme GPL-3.0
3 GiB
Languages
C++ 73.7%
HTML 8.8%
C 7%
TypeScript 4.8%
Tcl 2.5%
Other 3.1%