processing_time_s is set inside RunPipeline, so it measures one pass. A rotation two-pass run integrates everything twice and the beam-stop / beam-centre pre-scan happens before either pass, none of which the reported number saw: on an 18 Mpx dataset it printed 7.58 s for a run that took 23.46 s. Time the run in Run(), where every pass is inside, and report that. The last pass is still printed alongside it when there was more than one, because the gap between them is what the second pass costs. The frame rate and throughput stay per-pass: they say how fast rugnux moves through images, which running a second pass does not change. Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Jungfraujoch
Application to receive data from the PSI JUNGFRAU and EIGER detectors.
All documentation is now placed in docs/ subdirectory and for the current version hosted on Jungfraujoch Read The Docs page.