leonarski_fandClaude Opus 5 1df9556ec1 Bragg integration: default the radial background correction off again
Auto rode in with the ice work rather than on its own evidence, and measured over
the 37-crystal rotation battery it does not carry itself yet. It TARGETS
correctly - it fires on ten crystals and every one is ice-positive, no failures,
no space-group changes - but it costs 1.35x the wall clock (median +3 s per
crystal, worst +29 s) and on the merge statistics it is the familiar sign-mixed
trade: high-shell CC1/2 worse on three of the four crystals that move materially,
mean -0.76.

The case for it is real but rests on agreement with a fixed external model - 43 %
of the ice bands' excess amplitude removed on smooth ice, the effect 7x stronger
inside the bands than outside - which is the better arbiter and also the narrower
one. That deserves settling on its own, not riding along with a set of ice
defaults. `--background-radial=auto` keeps it a flag away.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-08-07 00:29:42 +02:00
2026-07-11 07:19:11 +02:00
2026-07-19 09:39:28 +02:00
2025-12-04 11:56:14 +01:00
2026-07-13 13:54:03 +02:00
2026-07-12 19:42:29 +02:00
2026-03-26 20:50:33 +01:00
2026-06-23 20:29:49 +02:00
2026-06-23 20:29:49 +02:00
2026-07-19 09:39:28 +02:00
2026-07-12 19:42:29 +02:00
2026-07-19 09:39:28 +02:00
2026-06-13 21:27:41 +02:00
2026-06-23 20:29:49 +02:00
2024-11-22 21:25:20 +01:00
2024-12-02 21:17:14 +01:00
2025-10-25 22:05:47 +02:00
2026-07-03 19:18:56 +02:00
2026-06-23 20:29:49 +02:00
2024-12-02 21:17:14 +01:00
2026-06-23 20:29:49 +02:00
2026-07-28 21:58:00 +02:00

Jungfraujoch

Application to receive data from the PSI JUNGFRAU and EIGER detectors.

All documentation is now placed in docs/ subdirectory and for the current version hosted on Jungfraujoch Read The Docs page.

S
Description
Jungfraujoch Data Acquisition System
Readme GPL-3.0
3 GiB
Languages
C++ 73.7%
HTML 8.8%
C 7%
TypeScript 4.8%
Tcl 2.5%