rugnux: the typed-angle rule of -C applies to a cell typed on the command line only
A joint run that processes a failed sweep again hands it the reference sweep's measured cell as fixed_reference_unit_cell. Its angles are never the literal 90 or 120, so the rule reading the crystal system off the typed angles pushed every such rerun to P 1 (or, on a lucky bit pattern, to a wrong system). The rule now fires only for a cell given with -C. Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01UqXYdJDrM65gxsCn2PrbfK
This commit is contained in:
1 parent
551ccb7eb1
commit
d2e6c85edb
1 file changed
+5
-2
@@ -939,6 +939,7 @@ struct RugnuxCli {
|
||||
bool anomalous_mode = false;
|
||||
const gemmi::SpaceGroup *space_group = nullptr;
|
||||
std::optional<UnitCell> fixed_reference_unit_cell;
|
||||
bool unit_cell_typed = false; // -C on the command line, not a cell a joint run hands a sweep
|
||||
std::optional<gemmi::CrystalSystem> fixed_lattice_system; // from a -C cell without -S
|
||||
std::optional<int64_t> max_spot_count_override;
|
||||
float sigma_spot_finding = SpotFindingSettings{}.signal_to_noise_threshold;
|
||||
@@ -1259,6 +1260,7 @@ int RugnuxCli::Parse(int argc, char **argv) {
|
||||
exit(EXIT_FAILURE);
|
||||
}
|
||||
fixed_reference_unit_cell = uc;
|
||||
unit_cell_typed = true;
|
||||
logger.Info(
|
||||
"Fixed reference unit cell set: a={:.3f} b={:.3f} c={:.3f} alpha={:.3f} beta={:.3f} gamma={:.3f}",
|
||||
uc->a, uc->b, uc->c, uc->alpha, uc->beta, uc->gamma);
|
||||
@@ -2006,8 +2008,9 @@ int RugnuxInputRun::PrepareRugnuxInput() {
|
||||
// never above or below, and only the space group within it is searched. Three 90s: orthorhombic,
|
||||
// or tetragonal / cubic where the lengths are equal within the usual tolerance; two 90s and a
|
||||
// 120: hexagonal; two 90s: monoclinic; three equal angles: rhombohedral; anything else names a
|
||||
// triclinic lattice, whose group is P 1 - and the run then goes as with -S P1.
|
||||
if (fixed_reference_unit_cell && space_group == nullptr) {
|
||||
// triclinic lattice, whose group is P 1 - and the run then goes as with -S P1. Only a cell typed by
|
||||
// the user: a measured cell a joint run hands a sweep to process again has no literal angles.
|
||||
if (fixed_reference_unit_cell && unit_cell_typed && space_group == nullptr) {
|
||||
const auto &c = *fixed_reference_unit_cell;
|
||||
const int n90 = (c.alpha == 90.0f) + (c.beta == 90.0f) + (c.gamma == 90.0f);
|
||||
const bool has120 = c.alpha == 120.0f || c.beta == 120.0f || c.gamma == 120.0f;
|
||||
|
||||
Reference in new issue