30 lines
1.3 KiB
Markdown
30 lines
1.3 KiB
Markdown
# Changelog
|
|
## 0.2.70
|
|
|
|
### 0.2.69
|
|
- check beamline state before running raster, rotation and automation
|
|
- lowered polling rate of daq status to improve GUI performance
|
|
- robot drys then parks after repeated mount failures
|
|
### 0.2.68:
|
|
- added check box to numberlineedits to switch between user input and spreadsheet
|
|
- re-enabled MLprediction
|
|
- fixed bug in gui where manual sample couldnt be created when run nubmer was negative.
|
|
- Combined beamline view now split vertically not horizontally
|
|
- New error handling in DAQ for robot mounting errors
|
|
- Error box pop ups in GUI when sample gripper detection error occurs
|
|
- Automation queue pauses if sample gripper detection error occurs multiple times to allow robot dry, if continues stops and wiats for user interverntion
|
|
- added ingest_scan to send rotation and screening result to db
|
|
|
|
### 0.2.67:
|
|
- added run number to sampleshortinfo
|
|
- ingest raster result, including beam center to database
|
|
- aerotech goes to mount postion for manual mount
|
|
- logger config correctly expands file path for logger location.
|
|
- smart_rotiation_panel fix - but will be mvoed to DAQ in future update
|
|
- Fluoresence scan can be saved to CSV with right click
|
|
- Wait for ready before sending Tell to dry
|
|
|
|
### 0.2.66:
|
|
- moved rastergridingestmodel and centreofmassmodel from models to raster_grid.py
|
|
- after raster load closest image to new centre
|