Files
AareDAQ/daq/docs/CHANGELOG.md
T
appleb_m 247d50141b
Build and Publish / build (push) Successful in 23s
Build and Publish / Build and Deploy Docs (push) Successful in 36s
added # to markdown files, changed index filepath in docs for autodeployment
2026-01-05 16:01:16 +01:00

1.3 KiB

Changelog

0.2.70

0.2.69

  • check beamline state before running raster, rotation and automation
  • lowered polling rate of daq status to improve GUI performance
  • robot drys then parks after repeated mount failures

0.2.68:

  • added check box to numberlineedits to switch between user input and spreadsheet
  • re-enabled MLprediction
  • fixed bug in gui where manual sample couldnt be created when run nubmer was negative.
  • Combined beamline view now split vertically not horizontally
  • New error handling in DAQ for robot mounting errors
  • Error box pop ups in GUI when sample gripper detection error occurs
  • Automation queue pauses if sample gripper detection error occurs multiple times to allow robot dry, if continues stops and wiats for user interverntion
  • added ingest_scan to send rotation and screening result to db

0.2.67:

  • added run number to sampleshortinfo
  • ingest raster result, including beam center to database
  • aerotech goes to mount postion for manual mount
  • logger config correctly expands file path for logger location.
  • smart_rotiation_panel fix - but will be mvoed to DAQ in future update
  • Fluoresence scan can be saved to CSV with right click
  • Wait for ready before sending Tell to dry

0.2.66:

  • moved rastergridingestmodel and centreofmassmodel from models to raster_grid.py
  • after raster load closest image to new centre