GUI: fix bug in rotationdatacollection for single image screening
This commit is contained in:
@@ -136,16 +136,36 @@ class RotationDataCollectionPanel(ScanSettingsPanel):
|
||||
logger.error("Cannot run measurement because of check")
|
||||
return
|
||||
screening_settings = self.screening_type.currentData()
|
||||
r = RotationScanRequest(
|
||||
file_prefix=str(add_screening_to_path(self._filename)),
|
||||
start_omega_deg=self.start_angle.value,
|
||||
wedge_omega_deg=self.screening_image_angle.value,
|
||||
incr_omega_deg=screening_settings["omega_step_deg"],
|
||||
steps=screening_settings["steps"],
|
||||
dtz=self._dtz,
|
||||
transmission=self._transmission,
|
||||
screening=True,
|
||||
exp_time_s=self.screening_image_time_enter.value)
|
||||
|
||||
is_single_image = (
|
||||
screening_settings["steps"] == 1
|
||||
and screening_settings["omega_step_deg"] == 0
|
||||
)
|
||||
|
||||
if is_single_image:
|
||||
r = RotationScanRequest(
|
||||
file_prefix=str(add_screening_to_path(self._filename)),
|
||||
start_omega_deg=self.start_angle.value,
|
||||
incr_omega_deg=self.screening_image_angle.value,
|
||||
steps=1,
|
||||
dtz=self._dtz,
|
||||
transmission=self._transmission,
|
||||
screening=False,
|
||||
exp_time_s=self.screening_image_time_enter.value,
|
||||
)
|
||||
else:
|
||||
r = RotationScanRequest(
|
||||
file_prefix=str(add_screening_to_path(self._filename)),
|
||||
start_omega_deg=self.start_angle.value,
|
||||
wedge_omega_deg=self.screening_image_angle.value,
|
||||
incr_omega_deg=screening_settings["omega_step_deg"],
|
||||
steps=screening_settings["steps"],
|
||||
dtz=self._dtz,
|
||||
transmission=self._transmission,
|
||||
screening=True,
|
||||
exp_time_s=self.screening_image_time_enter.value,
|
||||
)
|
||||
|
||||
self.rotation_scan.emit(r)
|
||||
self.viewer_track_online.emit()
|
||||
|
||||
|
||||
Reference in New Issue
Block a user