@@ -145,8 +145,8 @@ RATE=100;MODE=TRIGG;ENABLE=1;DC_REMOVE=1;APPLY_SCALE=1;NFFT=1024;DBG_PRINT=0;SOU
bMeasurese
## EPICS records
Each FFT plugin object will create a new asynportdriver-port named "PLUGIN.FFT<index>" (index is explaine above).
The reason for a dedicated asynport is to influence ecmc as little as possible.
The plugin contains a template file that will make most information availbe from records:
The reason for a dedicated asynport is to disturb ecmc as little as possible.
The plugin contains a template file, "ecmcPluginFFT.template", that will make most information availbe from records:
* Rawdata array (ro)
* FFT amplitude array (result) (ro)
* FFT x axis (frequencies) (ro)
@@ -157,16 +157,37 @@ The plugin contains a template file that will make most information availbe from
* Trigger cmd (rw)
* NFFT (ro)
The available records from this template file can be listed by the cmd:
The available records from this template file can be listed by the cmd (here two FFT plugins loaded):
```
dbgrep *FFT*
IOC_TEST:Plugin-FFT0-SampleRate-Act
IOC_TEST:Plugin-FFT1-SampleRate-Act
IOC_TEST:Plugin-FFT0-Mode-RB
IOC_TEST:Plugin-FFT1-Mode-RB
IOC_TEST:Plugin-FFT0-Source
IOC_TEST:Plugin-FFT0-Raw-Data-Act
IOC_TEST:Plugin-FFT0-Spectrum-Amp-Act
IOC_TEST:Plugin-FFT0-Spectrum-X-Axis-Act
IOC_TEST:Plugin-FFT1-Source
IOC_TEST:Plugin-FFT1-Raw-Data-Act
IOC_TEST:Plugin-FFT1-Spectrum-Amp-Act
IOC_TEST:Plugin-FFT1-Spectrum-X-Axis-Act
IOC_TEST:Plugin-FFT0-Enable
IOC_TEST:Plugin-FFT0-Trigg
IOC_TEST:Plugin-FFT1-Enable
IOC_TEST:Plugin-FFT1-Trigg
IOC_TEST:Plugin-FFT0-stat
IOC_TEST:Plugin-FFT0-NFFT
IOC_TEST:Plugin-FFT1-stat
IOC_TEST:Plugin-FFT1-NFFT
```
Note: The FFT asynparameters will not be visible by the ecmcReport iocsh command since the FFT records belong to another port.
## PLC interface
### PLC Functions
1. "fft_clear(arg0);" double fft_clear(index) : Clear/reset fft[index].
1. "fft_clear(arg0);" double fft_clear(index) : Clear/resets all buffers fft[index].
2. "fft_enable(arg0, arg1);" double fft_enable(index, enable) : Set enable for fft[index].
3. "fft_trigg(arg0);" double fft_trigg(index) : Trigg new measurement for fft[index]. Will clear buffers.
4. "fft_mode(arg0, arg1);" double fft_mode(index, mode) : Set mode Cont(1)/Trigg(2) for fft[index].
@@ -174,6 +195,7 @@ Note: The FFT asynparameters will not be visible by the ecmcReport iocsh command
### PLC Constants:
These constants are for use togheter with the above listed PLC functions:
1. "fft_CONT" = 1: FFT Mode: Continious
2. "fft_TRIGG" = 2: FFT Mode :Triggered
3. "fft_NO_STAT" = 0: FFT Status: Invalid state
@@ -187,6 +209,22 @@ This example load 2 FFT plugin objects:
1. SOURCE="plcs.plc0.static.sineval" which is a plc variable updated as a sinus with default freq 5 Hz.
2. SOURCE="ecmc.thread.latency.max". This is the execution latency of ecmc (in nanoseconds).
#### Example input signal
Epics record: IOC_TEST:Plugin-FFT0-Raw-Data-Act
|![ecmc dep](docs/ecmcPLC5HzRAW.png)|
| :---: |
|**Figure 1** Raw data. |
#### Example FFT result
Epics records:
* X = IOC_TEST:Plugin-FFT0-Spectrum-X-Axis-Act
* Y = IOC_TEST:Plugin-FFT0-Spectrum-Amp-Act
|![ecmc dep](docs/ecmcPLC5HzFFT.png)|
| :---: |
|**Figure 2** Resulting FFT amplitude. |
## Plugin info
```

BIN
docs/ecmcPLC5HzFFT.png Normal file

Binary file not shown.

After

Width:  |  Height:  |  Size: 21 KiB

BIN
docs/ecmcPLC5HzRAW.png Normal file

Binary file not shown.

After

Width:  |  Height:  |  Size: 103 KiB