Files
sics/site_ansto/instrument/hrpd/nxscripts.tcl
Ferdi Franceschini e1abaad64d Renamed crystal to Ge
r1368 | ffr | 2006-12-12 09:05:03 +1100 (Tue, 12 Dec 2006) | 2 lines
2012-11-15 12:55:36 +11:00

113 lines
3.6 KiB
Tcl

MakeNXScript
#nxscript createxml junk4.xml echidna.dic
proc getVal {msg} {
return [string trim [lindex [split $msg =] 1 ] ]
}
proc nxreopenfile {} {
global dataFileName;
nxscript reopen $dataFileName echidna.dic;
}
set dradius 1.25
set ndect 128
set tubedia 0.0254
set pi 3.1415926
#set angsep [expr $tubedia/$dradius *(180/$pi)]
set angsep 1.25
# stthmin = (180 - (1.25*127))/2
proc addnxentry {nxobj entryname scanVariable scanVarPos } {
global dradius ndect angsep;
putcommon $nxobj $entryname $scanVariable
putcrystal $nxobj
putmonitor $nxobj
putsample $nxobj
set scanVar_value [string trim [lindex [split [$scanVariable] =] 1]]
$nxobj putfloat $scanVariable $scanVar_value
# Add thetamin and stth to tharr(i)
set sampletwotheta [string trim [lindex [split [stth] =] 1]]
for {set i 0} {$i < $ndect} {incr i} {
set tharr($i) [expr ($i-63.5)*$angsep + $sampletwotheta]
}
$nxobj updatedictvar thetadim $ndect
$nxobj putarray dtheta tharr $ndect
$nxobj puttext dtype He-3 position sensitive detector, tube active length=335+/-5mm, tube diameter=25.4 +/- 0.8mm
$nxobj puttext ddesc 128 He-3 proportional counter detector tubes (GE Energy Reuter Stokes Inc. item=RS-P4-0814-217)
$nxobj putfloat dradius $dradius
$nxobj puttext dlayout area
$nxobj puthm dcounts hmm
$nxobj puthm deff hmm
$nxobj makelink scandata dcounts
$nxobj makelink scandata dtheta
$nxobj makelink scanvar $scanVariable
}
proc bm_addnxentry {nxobj entryname scanVariable scanVarPos } {
global dradius ndect angsep;
putcommon $nxobj $entryname $scanVariable
putcrystal $nxobj
putmonitor $nxobj
putsample $nxobj
set scanVar_value [string trim [lindex [split [$scanVariable] =] 1]]
$nxobj putfloat $scanVariable $scanVar_value
# Add thetamin and stth to tharr(i)
# $nxobj puttext dtype He-3 position sensitive detector, tube active length=335+/-5mm, tube diameter=25.4 +/- 0.8mm
# $nxobj puttext ddesc 128 He-3 proportional counter detector tubes (GE Energy Reuter Stokes Inc. item=RS-P4-0814-217)
# $nxobj putfloat dradius $dradius
$nxobj puttext dlayout point
$nxobj makelink scandata mdata
$nxobj makelink scanvar $scanVariable
}
proc putmonitor {nxobj} {
$nxobj puttext mmode [string trim [lindex [split [bm getmode] =] 1]]
$nxobj putfloat mpreset [string trim [lindex [split [bm getpreset] =] 1]]
$nxobj putint mdata [string trim [lindex [split [bm getcounts] =] 1]]
$nxobj putfloat mdistance [getVal [bm_distance]]
}
proc putsample {nxobj} {
$nxobj puttext saname [getVal [Sample]]
}
proc putcrystal {nxobj} {
$nxobj puttext ctype "Ge "
}
proc putcommon {nxobj entryName scanVariable} {
$nxobj updatedictvar entryName $entryName
$nxobj updatedictvar scan_variable $scanVariable
$nxobj puttext etitle [getVal [title]]
$nxobj puttext estart [sicstime]
$nxobj puttext eend [sicstime]
$nxobj puttext iname [getVal [instrument]]
# NXsource
$nxobj puttext sname OPAL
$nxobj puttext stype Reactor Neutron Source
$nxobj puttext sprobe Neutron
putsamplemotors $nxobj
putslitmotors $nxobj
putmonomotors $nxobj
}
proc putsamplemotors {nxobj} {
foreach motor { som schi sphi sx sy stth sth } {
$nxobj putfloat $motor [getVal [$motor] ];
}
}
proc putmonomotors {nxobj} {
foreach motor { mom mchi mphi mx my mtth mth } {
$nxobj putfloat $motor [getVal [$motor] ];
}
}
proc putslitmotors {nxobj} {
foreach motor {ss1u ss1d ss1l ss1r ss1vg ss1vo ss1hg ss1ho ss2u ss2d ss2l ss2r ss2vg ss2vo ss2hg ss2ho } {
$nxobj putfloat $motor [getVal [$motor] ];
}
}
publish addnxentry user