<?xml version="1.0" encoding="UTF-8"?>
|
|
<?oxygen RNGSchema="http://www.oasis-open.org/docbook/xml/5.0/rng/docbook.rng" type="xml"?>
|
|
<chapter xmlns="http://docbook.org/ns/docbook" xmlns:xlink="http://www.w3.org/1999/xlink"
|
|
version="5.0">
|
|
<info><title>Oxford 12T Magnet and/or Dilution Controller (via Labview App)</title><author>
|
|
<personname>Ferdi Franceschini</personname>
|
|
</author>
|
|
<date>2008-08-29 16:47</date>
|
|
</info>
|
|
<sect1>
|
|
<title>Configuration</title>
|
|
<para>For instrument scientists only</para>
|
|
<para>At the command line of your ics (instrument control server) computer type</para>
|
|
<para><command>runsics stop</command></para>
|
|
<para>This stops SICS, in preparation to make configuration changes.</para>
|
|
<para><command>configsics</command></para>
|
|
<para>This launches an application that will modify the SICS configuration for sample
|
|
environment. Follow the instructions at the top of the screen</para>
|
|
<para>Select </para>
|
|
<para><command>[x] 12tmagnet:</command></para>
|
|
<para><command>w</command> to write and exit configsics</para>
|
|
<para><command>runsics start</command></para>
|
|
<para>This will restart SICS with the new sample environment configuration. </para>
|
|
|
|
</sect1>
|
|
<sect1>
|
|
<title>Commands</title>
|
|
<annotation><para>from sct_oxford_labview.tcl</para></annotation>
|
|
<variablelist>
|
|
<varlistentry>
|
|
<term><command>oxfordsetfield </command><replaceable>n</replaceable></term>
|
|
<listitem>
|
|
<para>Set the magnetic field to <replaceable>n</replaceable> Tesla</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>oxfordsetrate </command><replaceable>n</replaceable></term>
|
|
<listitem>
|
|
<para>Set the magnet field ramp rate to <replaceable>n</replaceable> Tesla /
|
|
minute ??? check units</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>oxfordsethtemp </command><replaceable>n</replaceable></term>
|
|
<listitem>
|
|
<para>Set the Heliox temperature to <replaceable>n</replaceable> K </para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>oxfordsetdtemp </command><replaceable>n</replaceable></term>
|
|
<listitem>
|
|
<para>Set the Dilution Insert temperature to <replaceable>n</replaceable>
|
|
K</para>
|
|
</listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>oxfordseths </command><replaceable>ON/OFF</replaceable></term>
|
|
<listitem>
|
|
<para>Turn the heater switch <replaceable>ON/OFF</replaceable> ??? </para>
|
|
</listitem>
|
|
</varlistentry>
|
|
</variablelist>
|
|
</sect1>
|
|
<sect1>
|
|
<title>Parameters</title>
|
|
<variablelist><varlistentry>
|
|
<term><command>/sample/magnetic/field </command></term><listitem><para>???</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/magneticFieldCurrent </command></term><listitem><para>Magnet current (amps)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/magneticFieldTesla </command></term><listitem><para>Magnetic field (Tesla)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/start_magnetic </command></term><listitem><para>Start value for a magnetic field ramp (Tesla)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/end_magnetic </command></term><listitem><para>For a magnetic field ramp, this is the end value (Tesla)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/Temp </command></term><listitem><para>Temperature on main control sensor (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/Temp_s1 </command></term><listitem><para>Temperature on sensor 1 (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/Temp_s2 </command></term><listitem><para>Temperature on sensor 2 (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/Temp_s3 </command></term><listitem><para>Temperature on sensor 3 (K)</para></listitem>
|
|
</varlistentry>
|
|
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/start_temperature_s1 </command></term><listitem><para>Start value for a temperature ramp using sensor 1 (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/end_temperature_s1 </command></term><listitem><para>End value for a temperature ramp using sensor 1 (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/start_temperature_s2 </command></term><listitem><para>Start value for a temperature ramp using sensor 2 (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/end_temperature_s2 </command></term><listitem><para>End value for a temperature ramp using sensor 2 (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/start_temperature_s3 </command></term><listitem><para>Start value for a temperature ramp using sensor 3 (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/end_temperature_s3 </command></term><listitem><para>End value for a temperature ramp using sensor 3 (K)</para></listitem>
|
|
</varlistentry>
|
|
|
|
<!-- Setting Magnetic field -->
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/fieldSetPoint </command></term><listitem><para>Setpoint for magnetic field (Tesla)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/fieldSetRate </command></term><listitem><para>Magnetic field rate (Tesla/min)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/HelioxTempSetPoint </command></term><listitem><para>Setpoint for Heliox (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/HelioxTempReading </command></term><listitem><para>Temperature reading for Heliox (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/DilutTempSetPoint </command></term><listitem><para>Setpoint for Dilution Insert (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/DilutTempReading </command></term><listitem><para>Temperature reading for Dilution Insert (K)</para></listitem>
|
|
</varlistentry>
|
|
|
|
<!-- If TUNING -->
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/set_rate </command></term><listitem><para>Magnetic field rate (Tesla/min)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/set_magneticField </command></term><listitem><para>Setpoint for magnetic field (Tesla)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/set_DiluxTemp </command></term><listitem><para>Setpoint for Dilution Insert (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/set_HelioxTemp </command></term><listitem><para>Setpoint for Heliox (K)</para></listitem>
|
|
</varlistentry>
|
|
<varlistentry>
|
|
<term><command>/sample/magnetic/set_HeaterSwitch </command></term><listitem><para>Turn heater switch ON and OFF</para></listitem>
|
|
</varlistentry>
|
|
|
|
</variablelist>
|
|
</sect1>
|
|
<sect1>
|
|
<title>Description</title>
|
|
<para>No additional descriptions available at this time. </para>
|
|
</sect1>
|
|
<sect1>
|
|
<title>Known Issues</title>
|
|
<para>Alerts the user to known operational problems</para>
|
|
</sect1>
|
|
<sect1>
|
|
<title>Troubleshooting</title>
|
|
<para>What to do if things go wrong</para>
|
|
</sect1>
|
|
</chapter>
|