SICS-418 Make sure hnotify sends messages as hdbevents when using the
JSON protocl
site_ansto/instrument/config/hmm/hmm_object.tcl
Initialise the hmm object to make sure the read type is set.
nxscripts_common_1.tcl
Set the read type when saving the hmm data.
server_config.tcl
Fix the autosave command so that you can enable/disable autosave while
the histogram memory is running.
protocol.c
Reduce noise in log files when using the JSON protocol. Don't log
messages generated during macro execution (ie within a TCL proc).
motor.c:MotorStatus
Abort the current operation, the scan command and batch files when a
motor object returns a hardware fault status value.
motor_dmc2280.c
set driver status to HWFault when the driver is in the error state.
r3251 | ffr | 2011-09-23 08:49:00 +1000 (Fri, 23 Sep 2011) | 25 lines
You can now run the oscillating collimator for a specified number of cycles.
A MOTEND event is now sent when the oscillator stops.
Also temporarily set status to eEager to allow changing the motor accesscode parameter while something else is running, (eg a counter)
motor.c
finishDriving is no longer static so we can call it from the oscilator and generate a MOTEND event.
west4100.c
Return 'success' from wrapper on "controlsensor" and "sensorlist" queries so we can test and capture their values in scripts.
Makefile
Compile the quokka beamstopaction object
site_ansto.c
Add the MakeActionObject command. Currently only makes the hardcoded beamstopaction object
obpar.c
Report object name and parameter on an illegal attempt to set a parameter
hmm_configuration_common_1.tcl
Add oscillating collimator control flag for Wombat. If true we use hmm to start the histogram server instead of hmc. TODO remove hmc and always use hmm.
hipd/config/motors/motor_configuration.tcl
Don't load anticollider config twice. Fix oct limits
wombat_configuration.tcl
Environment configuration must be loaded before running server_init.
hrpd/config/hmm/hmm_configuration.tcl
Fix default time-bin to match 10Hz frame frequency
hrpd/config/motors/motor_configuration.tcl
Added dummy motor for testing.
reflectometer/config/hmm/detector.tcl
Fill in dhv1 configuration parameters.
sans/config/hmm/detector.tcl
Enable detector voltage control
sans/config/hmm/hmm_configuration.tcl
SICS-227 set default resolution to 192x192
sans/config/motors/motor_configuration.tcl
Added dummy motor for testing
quokka parameters.tcl
Fix L2mm calculation, Fix SICS-228 users cannot set rotapdeg
beamstopaction.[ch]
NEW: Implements an action command to drive the quokka beamstops up and down.
r2670 | ffr | 2008-08-07 13:17:29 +1000 (Thu, 07 Aug 2008) | 53 lines
Remove any prior interest for this motor and pCon before installing the new one. Limits the interest callback message count to one.
r1987 | dcl | 2007-05-25 16:17:44 +1000 (Fri, 25 May 2007) | 3 lines