Split module handling code from the dispatcher.
The new class for managing Modules is called SecNode.
* change logging to no longer need a reference to modobj
* modules get a reference to the secnode obj instead of the
dispatcher
* intermediate usage fixes for frappy_psi/sea
Change-Id: Ifee4bb47aa7a4508bb4a47c9a5873b7e2d5faf67
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32249
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
- frappy_psi.channelswitcher: use isBusy instead of checking value and target
- frappy_psi.ls372: remove underflow mechanism
- frappy_psi.parmod.SwitchDriv: switch the controlled module also when not buys
in SecopClient.disconnect joinng the reconnect thread may take
up to 10 s, because of the time.sleep(10) call in the reconnect
thread.
change the _shutdown attribute from bool to an Event, and
use Event.wait instead of time.sleep
Change-Id: Icea6a14ad73df0b3d26ef45806f4c05e6bf18492
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32137
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in the previous version FloatRange(max=100) was neither working
properly nor complaining, because the maxval=None default was
overriding the value for max.
possible fixes:
- raise an error when min/max used as argument (confusing for
the programmer, as it is a property)
- allow both versions minval/maxval and min/max (more code)
- use min/max and a pylint directive here (the only thing to
take care is not to use the min/max builtin in __init__)
this change uses the last option for the fix
Change-Id: Iff0e0c4d0d7b165003bdeffa67a93a1cd7f29eea
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31982
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
reading back the target does not work properly, because
a) the readback value might be delayed
b) there is no command to read back the target, SETP?1
is returning the working setpoint, which might be distinct
in case of a ramp
Change-Id: I0da2dbfc1a8ddbecbae6d0456ff64e008bc56336
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31983
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
the reasonly class frappy_psi.parmod.Par represents a parameter
or a component of a tuple parameter
Change-Id: I47208c9d7a6fc377cd56b82cc6a9e8cdb433fe8e
on shutdown, time.sleep(10) is blocking the reconnect thread.
change the _shutdown attribute from bool to an Event, and
use Event.wait instead of time.sleep
Change-Id: Icea6a14ad73df0b3d26ef45806f4c05e6bf18492