including a config file and overriding some properties is
helpful when we do not want to modify the original config
but run it with sligthly different properties.
this involves some redesign a.o.:
- modules are collected in a dict instead of a list in
order for 'override' to find the related module
- checking for duplicates happens in the Collector
Do not warn when included file does not end with '_cfg.py',
as this may be intentional, in case a file is only used
via 'include' and not as cfg file alone.
+ remove unused method Collector.append
+ complain with specific error message when Node is not given
Change-Id: Id568f04d6d84622ef2547412eb6f288fcebf986f
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/36357
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- instead to show first current 'value' and 'status', and then
the changes, show changes only - this way updates appear
in the expected order
- for this SecopClient.register_callback needs a 'callimmediately'
argument
Change-Id: I3e91c2c15bca7fee2eba3b1bf1dd27313da3ae29
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/36291
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
a property declared in a base class may be overriden
with a parameter in a subclass. this is already allowed.
if then, in the subsubclass it is overridden by a bare value,
it fails.
Patchset 1: add a test for this
Patchset 4: add the fix
Change-Id: Ia5a26076a9ee98439932643a03878342d56f8396
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35932
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
The test for method names 'read_<param>' and 'write_<param>'
without a defined parameter is simplified. We do not check
anymore method names from base classes. Base classes
inheriting from HasAccessible are checked anyway at the
place they are defined.
+ add a test for it
+ move some tests to a new file test_all_modules.py, as
test_modules.py is getting too long
+ fix missing doc string (frappy.simulation.SimDrivable.stop)
Change-Id: Id8a9afe5c977ae3b1371bd40c6da52be2fc79eb9
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35503
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
This is meant to replace change 33375.
Optional commands and parameters may be declared with the argument
optional=True. In principle, optional commands are not really needed
to be declared, but doing so is nice for documentation reasons
and for inherited accessible properties.
Optional parameters and commands can not be used and are not
exported als long as they are not overridden in subclasses.
- add a test for this
+ fix an issue with checking for methods like read_<param> without
<param> being a parameter
Change-Id: Ide5021127a02778e7f2f7162555ec8826f1471cb
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35495
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Add a new custom module property 'original_id' indicating
the equipment_id the modules originally belongs to.
This property is only given, when distinct from the equipment_id
of the SEC node.
It happens when multiple config files are given, for all modules
but the ones given in the first file, and for routed modules,
when multiple nodes are routed or own modules are given.
+ fix an issue in router: additional modules were ignore in case
of a single node.
+ small cosmetic changes in config.py reducing IDE complains
Change-Id: If846c47a06158629cef807d22b91f69e4f416563
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35396
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
In the previous code, the equipment_id was overridden by the
server name when the interface argument was given over
the commandline. This was leftover from the previous config
file format, where the config files not neccessarly needed
an equipment_id.
Change-Id: I2fc248372a7d2f61cc0690804268d6d066a0a9fa
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/35391
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
The options given in the node configuration may be used
for both SecNode (equipment_id) and Dispatcher (when the
frappy.protocol.router.Router is used as dispatcher).
It is correct that both remove the options known to them.
Change-Id: I2a34073e4e5490dcf8db577d9cb74788c0cb657b
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34989
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Under some condition (no general config file) it's possible that the
piddir and logdir as well are lists of pathes which creates some errors
during the server start
This problems occurs at least in NICOS test suite where no general
config file is defined.
Change-Id: I94c5db927923834c1546dbc34e2490b07b0bf111
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/34952
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Jens Krueger <jens.krueger@tum.de>