the previous version failed when timestamp was missing
Change-Id: I77e1fb81b19fb4ee2749d731bafacbac46132f8e
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32404
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Looked at this code again, and wondered why the default is not True.
It is far more probable that the programmer just forgets to set
this property to True than it would harm to do so.
Change-Id: I439aedbdfc9c2b12737e3ce1694e90550ddf0e78
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32270
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
bugfix: return only value of execCommand result, not qualifiers
Change-Id: Iff14779050daa9886e9f7d0396317c5a41695cd1
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32235
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- frappy_psi.channelswitcher: use isBusy instead of checking value and target
- frappy_psi.ls372: remove underflow mechanism
- frappy_psi.parmod.SwitchDriv: switch the controlled module also when not buys
- changes in return value of frappy_config command in sea
- do not store sea manager
Change-Id: I5bc1d9a281ad2285b90d3649b4c702a3501d451d
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32166
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in SecopClient.disconnect joinng the reconnect thread may take
up to 10 s, because of the time.sleep(10) call in the reconnect
thread.
change the _shutdown attribute from bool to an Event, and
use Event.wait instead of time.sleep
Change-Id: Icea6a14ad73df0b3d26ef45806f4c05e6bf18492
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32137
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
in the previous version FloatRange(max=100) was neither working
properly nor complaining, because the maxval=None default was
overriding the value for max.
possible fixes:
- raise an error when min/max used as argument (confusing for
the programmer, as it is a property)
- allow both versions minval/maxval and min/max (more code)
- use min/max and a pylint directive here (the only thing to
take care is not to use the min/max builtin in __init__)
this change uses the last option for the fix
Change-Id: Iff0e0c4d0d7b165003bdeffa67a93a1cd7f29eea
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31982
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
reading back the target does not work properly, because
a) the readback value might be delayed
b) there is no command to read back the target, SETP?1
is returning the working setpoint, which might be distinct
in case of a ramp
Change-Id: I0da2dbfc1a8ddbecbae6d0456ff64e008bc56336
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31983
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- get return value from teh frappy-config script in order
to detect failures
- call config_check not more than once within 1 sec
Change-Id: Ibe42e846521206463f2761d452aea7e558a36854
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32139
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
using super() in SimBase.__new__ fixes the problem
Change-Id: I18d0ba6ac476c2edb0d973090bcb09508a983d6a
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32136
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
- get_module is to be called when io is autocreated
- register_module is missing in playground
Change-Id: I28884575b71320667107c494473b0fc5d4363a50
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/32123
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
the reasonly class frappy_psi.parmod.Par represents a parameter
or a component of a tuple parameter
Change-Id: I47208c9d7a6fc377cd56b82cc6a9e8cdb433fe8e
on shutdown, time.sleep(10) is blocking the reconnect thread.
change the _shutdown attribute from bool to an Event, and
use Event.wait instead of time.sleep
Change-Id: Icea6a14ad73df0b3d26ef45806f4c05e6bf18492
assumptions about dispatcher in playground.py are no longer
valid.
- let Dispatcher class in playground inherit from real dispatcher
+ improve log messages
Change-Id: I2a9a9d532dabadc590543660c445c021dd2f2891
Reviewed-on: https://forge.frm2.tum.de/review/c/secop/frappy/+/31967
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Alexander Zaft <a.zaft@fz-juelich.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>