more cfg file fixes
Change-Id: I0ba86cd17bb07f480cac6f20994ee854c6e811ae
This commit is contained in:
parent
96a7e2109b
commit
ecef2b8974
@ -1,100 +0,0 @@
|
||||
Node('stressihtf2',
|
||||
'''[sim] Stressihtf2 box of MLZ Sample environment group
|
||||
|
||||
Controls an High Temperature Furnace with an Eurotherm and an PLC controlling some valves and checking cooling water.''',
|
||||
interface='tcp://10767',
|
||||
)
|
||||
|
||||
Mod('T_stressihtf2',
|
||||
'frappy.simulation.SimDrivable',
|
||||
description='Main temperature control node of Stressihtf2.',
|
||||
value=Param(
|
||||
datatype=FloatRange(unit='degC', minval=0.0),
|
||||
default=20.0,
|
||||
),
|
||||
target=Param(
|
||||
datatype=FloatRange(unit='degC', minval=0.0, maxval=2000.0),
|
||||
default=20.0,
|
||||
),
|
||||
extra_params=['ramp', 'regulationmode', 'abslimits', 'userlimits'],
|
||||
ramp=Param(
|
||||
datatype=FloatRange(unit='K/min', minval=0.0, maxval=600.0),
|
||||
description='target ramping speed in K/min.',
|
||||
default=60.0,
|
||||
),
|
||||
abslimits=Param(
|
||||
datatype=TupleOf(FloatRange(unit='degC', minval=0.0, maxval=2000.0), FloatRange(unit='degC', minval=0.0, maxval=2000.0)),
|
||||
default=(0.0, 2000.0),
|
||||
description='currently active absolute limits for the setpoint. depend on the regulationmode parameter (both/stick->0..600, tube->0..300K).',
|
||||
),
|
||||
userlimits=Param(
|
||||
datatype=TupleOf(FloatRange(unit='degC', minval=0.0, maxval=2000.0), FloatRange(unit='degC', minval=0.0, maxval=2000.0)),
|
||||
default=(0.0, 300.0),
|
||||
description='current user set limits for the setpoint. must be inside abslimits.',
|
||||
readonly=False,
|
||||
),
|
||||
meaning=('temperature_regulation', 10),
|
||||
)
|
||||
|
||||
Mod('T_stressihtf2_sample',
|
||||
'frappy.simulation.SimReadable',
|
||||
description='(optional) Sample temperature sensor.',
|
||||
visibility='expert',
|
||||
value=Param(
|
||||
default=300.0,
|
||||
datatype=FloatRange(unit='degC', minval=0.0),
|
||||
),
|
||||
meaning=('temperature', 9),
|
||||
)
|
||||
|
||||
Mod('stressihtf2_n2',
|
||||
'frappy.simulation.SimWritable',
|
||||
description='Switches the N2 gas inlet on or off.',
|
||||
visibility='expert',
|
||||
value=Param(
|
||||
default='off',
|
||||
datatype=EnumType('', off=0, on=1),
|
||||
),
|
||||
target=Param(
|
||||
datatype=EnumType('', off=0, on=1),
|
||||
default='off',
|
||||
),
|
||||
)
|
||||
|
||||
Mod('stressihtf2_he',
|
||||
'frappy.simulation.SimWritable',
|
||||
description='Switches the He gas inlet on or off.',
|
||||
visibility='expert',
|
||||
value=Param(
|
||||
default='off',
|
||||
datatype=EnumType('', off=0, on=1),
|
||||
),
|
||||
target=Param(
|
||||
datatype=EnumType('', off=0, on=1),
|
||||
default='off',
|
||||
),
|
||||
)
|
||||
|
||||
Mod('stressihtf2_lamps',
|
||||
'frappy.simulation.SimWritable',
|
||||
description='Switches the heating lamps on or off.',
|
||||
visibility='expert',
|
||||
value=Param(
|
||||
default='on',
|
||||
datatype=EnumType('', off=0, on=1),
|
||||
),
|
||||
target=Param(
|
||||
datatype=EnumType('', off=0, on=1),
|
||||
default='on',
|
||||
),
|
||||
)
|
||||
|
||||
Mod('stressihtf2_water_ok',
|
||||
'frappy.simulation.SimReadable',
|
||||
description='Readout of the cooling water state.',
|
||||
visibility='expert',
|
||||
value=Param(
|
||||
default='ok',
|
||||
datatype=EnumType('', failed=0, ok=1),
|
||||
),
|
||||
)
|
@ -46,7 +46,7 @@ Mod('res',
|
||||
),
|
||||
value=Param(
|
||||
default=99.0,
|
||||
datatype=FloatRange(unit='Ohm'),
|
||||
datatype={'type': 'double', 'unit': 'Ohm'},
|
||||
),
|
||||
)
|
||||
|
||||
|
Loading…
x
Reference in New Issue
Block a user