- SECoP modules are accessible as objects in the main python module
- parameters are accessed as attributes of these objects
- __repr__ is used for listing all parameters
- __call__ is used for 'change target and wait until no more busy'
typically used from a python interpreter or in a jupyter notebook
Change-Id: Idb55684eeff6d1262e5d1517a3ff934f1c1bf208
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28980
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
for easier configuration of multiple servers on the same machine,
FRAPPY_* env. variables are overriding the values from the
general config file
Change-Id: Ifb00dae482dd366bd4b7951c76164af91cad9fc2
- repeated errors on poller are only once logged (per poll
function / read_* method)
- during exception handling, silent=True on a SECoP error indicates
that the error is already logged
+ fix the name of HardwareError
+ add test for consistency of SECoPErrors
+ catch socket.timeout in AsynTcp
Change-Id: I9df6c775cc19553b22a4d6e39591092adf7ff9a1
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28139
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
in secop.proxy the callers modules method announceUpdate is
called from an other thread while the accessLock is locked,
creating a deadlock. solve this by creating an other lock
'updateLock' for the update.
+ add status parameter even to non-Readable proxy modules,
in order to indicate a failed connection
+ fix an error in secop_psi/softcal.py
Change-Id: Iae7c6d5a74001150a47aa9dc99209c15d972cd5e
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28130
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
This valve needs 8 turns to open. As the encoder forgets
the number if turns on power cycle, a home switch is
mounte, which engages during the last turn when closing.
The final close position is determined by closing the valve
with a defined motor current/torque.
+ fix an issue in StateMachine.start: the first cycle
must be called after the new state is assigned
Change-Id: I34cd05d10d97b043f9e3126310943b74ee727382
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28030
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Enrico Faulhaber <enrico.faulhaber@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
When several poller threads are using the same io, the resposivity
of client requests is reduced, as every thread first finishes
its pending communication requests, before it is the turn of the
request thread. This is solved by using one common poller thread
for all modules sharing the same communicator.
+ fix an issue with overriding a property with a parameter, as
this is the case for pollperiod (cfg was applied to property
instead of overriding parameter)
+ separate setFastPoll arguments into flag and fast interval
+ fix missing announceUpdate call when read function fails
+ fix mechanism for triggering polls after an io connection
reconnected again.
Change-Id: I1115a61fae3de80d18416e61f40b52a0eebb637c
Reviewed-on: https://forge.frm2.tum.de/review/c/sine2020/secop/playground/+/28021
Tested-by: Jenkins Automated Tests <pedersen+jenkins@frm2.tum.de>
Reviewed-by: Markus Zolliker <markus.zolliker@psi.ch>
this apllies only to the argument in frappy - in the case
of all members optional, they are put into the description,
not honouring issue 69
Change-Id: I8e9e4d9ef6bd5b9bb2748f3c6116b7094cd9e927
- fix omit_unchanged
- names too short
+ other pylint complains
Change-Id: I3c277b461fad1a5fdf8e76ff1cc42b8742d1de16
Change-Id: I58fb64f91bcc2efef20df68f5c63a64315413286
- fix CommandType.__repr__
- secop/modules.py: command properties are allowed to be configured:
- section 2: remove comment and rename
- section 3: all accessible properties should be checked
- command description should be inherited also when taken from docstring
- move test for command inheritance to test_modules.py
- added tests to check for valid properties of commands
Change-Id: I5fd04e03be1faec5e54fed9735620bc5dc0f89c0
- asynconn: raise * from *
- asynconn: correct handling for timeout in AsynSerial
- add new py35compat
- target unit $
Change-Id: I052185ad3ebb3e3d1e3374f7ece9c7df06223951
- driving with a generator
- 3 phases
1) find active range (low current, far movement until force over hysteresis)
2) release force until well below target
3) adjusting using pid_p. (this is in fact an integral factor)